Operating instructions

32DDO03.A
3 - 1
III. MAINTENANCE
egular maintenance of the RICON RDO2700 Series Power Swing Door Operator is required
to provide optimum performance. During the Ricon warranty period, maintenance inspec-
tions must be performed by an authorized Ricon service technician at least once every six
months, or sooner depending on usage. After the warranty period, maintenance inspections are
recommended for the same time intervals.
WARNING!
THIS RICON PRODUCT IS HIGHLY SPECIALIZED. MAINTENANCE AND REPAIRS MUST BE
PERFORMED ONLY BY AN AUTHORIZED RICON SERVICE TECHNICIAN USING ONLY RICON
REPLACEMENT PARTS. MODIFYING OR FAILING TO PROPERLY MAINTAIN THIS PROD-
UCT WILL VOID THE WARRANTY AND MAY RESULT IN UNSAFE OPERATING CONDITIONS.
TO MAINTAIN THE WARRANTY, THIS PRODUCT MUST BE INSPECTED AT LEAST EVERY
SIX MONTHS OR SOONER DEPENDING ON USAGE.
A. MAINTENANCE INFORMATION
Additional maintenance information is available in the RDO2700 Series Power Swing Door
Service manual, part number 32DDO04. This manual is available from Ricon in printed hard
copy, or at the Ricon website in PDF format. The website is located at www.riconcorp.com.
B. MAINTENANCE SCHEDULE
Refer to Table 3-1 for the maintenance schedule
TABLE 3-1: SIX-MONTH MAINTENANCE CHECK
INSPECTION AREA ACTION
Rod ends and hex rod.
Clean, tighten, and lubricate with light oil as
needed.
Check door motion for complete
travel.
Adjust as needed.
Check all fasteners for tightness. Tighten as needed.
Check electrical crossover cable for
interference with moving members.
Adjust and secure as needed.
Check manual operation of power
door operators.
Ensure proper operation.
THE FOLLOWING STEPS REQUIRE REMOVAL OF THE DOOR PANELS
Check spur gear and bushings for
signs of wear.
Replace if needed.
Check wiring and limit switches for
proper connection and/or interface
points.
Adjust as required.
END OF TABLE
R