Service manual

32DDO04.A
3
-
1
III. MAINTENANCE
egular routine maintenance of the RICON RDO2700 Series Power Swing Door Operators is required to pro-
vide optimum performance. During the Ricon warranty period, maintenance inspections must be performed by
an authorized Ricon service technician at least once every six months, or sooner depending on usage. After
the warranty period, maintenance inspections are recommended for the same time intervals.
WARNING!
THIS RICON PRODUCT IS HIGHLY SPECIALIZED. MAINTENANCE AND REPAIRS MUST BE PERFORMED
BY AN AUTHORIZED RICON SERVICE TECHNICIAN USING RICON REPLACEMENT PARTS. MODIFYING
OR FAILING TO PROPERLY MAINTAIN THIS PRODUCT WILL VOID THE WARRANTY, AND MAY RESULT IN
UNSAFE OPERATING CONDITIONS. TO MAINTAIN THE WARRANTY, THIS PRODUCT MUST BE
INSPECTED AT LEAST EVERY SIX MONTHS, OR SOONER DEPENDING ON USAGE.
A. MAINTENANCE SCHEDULE
TABLE 3-1: SIX-MONTH MAINTENANCE CHECK
INSPECTION AREA ACTION
Rod ends and hex rod.
Clean, tighten, and lubricate with light oil
as needed.
Check door motion for complete travel. Adjust as needed.
Check all fasteners for tightness. Tighten as needed.
Check electrical crossover cable for interference with
moving members.
Adjust and secure as needed.
Check manual operation of power door operators. Verify proper operation.
NOTE: The following steps require removal of the door panels.
Check spur gear and bushings for signs of wear. Replace if needed.
Check wiring and limit switches for proper connection
and/or interface points.
Adjust as required.
END OF TABLE
R