Service manual

32DDO06.A
3
-
1
III. MAINTENANCE
egular maintenance of the RICON RDO2900 Series Internal Power Swing Door Operator is required to provide
optimum performance. During the Ricon warranty period, maintenance inspections must be performed by an
authorized Ricon service technician at least once every six months, or sooner depending on usage. After the
warranty period, maintenance inspections are recommended at the same time intervals.
WARNING!
THIS RICON PRODUCT IS HIGHLY SPECIALIZED. MAINTENANCE AND REPAIRS MUST BE
PERFORMED BY A RICON AUTHORIZED SERVICE TECHNICIAN USING RICON REPLACEMENT PARTS.
MODIFYING OR FAILING TO PROPERLY MAINTAIN THIS PRODUCT WILL VOID THE WARRANTY, AND
MAY RESULT IN UNSAFE OPERATING CONDITIONS. TO MAINTAIN THE WARRANTY, THIS PRODUCT
MUST BE INSPECTED AT LEAST EVERY SIX MONTHS, OR SOONER DEPENDING ON USAGE.
A. MAINTENANCE SCHEDULE
TABLE 3-1: SIX-MONTH MAINTENANCE CHECK
INSPECTION AREA ACTION
Rod ends and hex rod. Clean, tighten, and lubricate with light
oil as needed.
Check door motion for complete travel. Adjust as needed.
Check all fasteners for tightness. Tighten as needed.
Check electrical crossover cable for interference with mov-
ing members.
Adjust and secure as needed.
Check manual operation of power door operators. Verify proper operation.
NOTE: The following steps require removal of the door panels.
Check spur gear and bushings for signs of wear. Replace if needed.
Check wiring and limit switches for proper connection and/or
interface points.
Adjust as required.
END OF TABLE
R