Full Product Manual
chemical environment and service temperature, should be
completed. Consult Press Fitting System manufacturer
for selection information.
Pre-Operation Inspection
WARNING
Daily before use, inspect your
press tool and cor rect any
problems to reduce the risk of
serious in jury from electric
shock, crushing injures, attach-
ment failure and other causes, and prevent tool
damage.
1. Switch OFF the tool and remove battery/AC Adapter
from tool.
2. Clean any oil, grease or dirt from the equipment,
especially the handles and controls. This aids inspec-
Specifications
Standard Equipment
Refer to the RIDGID catalog for details on equipment
supplied with specific tool catalog numbers.
NOTE! RIDGID press tool attachments are offered in two
“series”
• Standard Series
• Compact Series
These attachment series are not interchangeable. Stan dard
series attachments will only work with standard series
tools (RP 350, RP 351, RP 342-XL, RP 340, RP 330,
320-E, CT-400). Compact series attachments will only
work with compact series tools (RP 240, RP 241, RP 200,
RP 210, 100B).
Selection of appropriate materials and join-
ing methods is the responsibility of the system designer
and/or installer. Before any installation is attempted, care-
ful evaluation of the specific service environment, including
999-995-220.10_REV. B
7
RP 350/RP 351 Press Tools
NOTICE
RP 350 Pistol Press Tool RP 351 Inline Press Tool
Attachments.................RIDGID Standard Series RIDGID Standard Series
Stroke Length ..............1.57" (40 mm) 1.57" (40 mm)
Motor
Voltage.....................18 V DC rated 18 V DC rated
Amperage.................23 A 23 A
Power.......................480 Watts 480 Watts
Ram Force...................7,200 lbs. (32 kN) 7,200 lbs. (32 kN)
Head Rotation..............360° 360°
Duty Cycle ...................3 Press /min. 3 Press /min
Power Supply ..............RIDGID RB-18XX Series 18 V Li-Ion Battery Pack or RIDGID RPA 120/220 AC Power Adapter
(See Optional Equipment Section)
Bluetooth Range ..........33 ft. (10 m) 33 ft. (10 m)
Permissible Humidity.....80% maximum 80% maximum
Operating Temperature
Range.............................15° F to 122° F (-10° C to 50° C) 15° F to 122° F (-10° C to 50° C
Storage Temperature.....32° F to 113° F (0° C to 45° C) 32° F to 113° F (0° C to 45° C)
Weight (no battery/
attachment)....................7.83 lbs (3.55 kg) 7.83 lbs (3.55 kg)
Dimensions..................11.3" x 11.0" x 3.1" 15.7" x 4.65" x 3.1"
287 mm x 279 mm x 77 mm 398 mm x 118 mm x 77 mm
Sound Pressure (L
PA
)*.....<74.5 dB(A), K=3 dB(A) <74.5 dB(A), K=3 dB(A)
Vibration* .....................<1.13 m/s
2
, K=1.5 <1.13 m/s
2
, K=1.5
* Sound and Vibration measurements are measured in accordance with a standardized test per Standard EN 62481-1.
- Vibration levels may be used for comparison with other tools and for preliminary assessment of exposure.
- Sound and vibration emissions may vary due to your location and specific use of these tools.
- Daily exposure levels for sound and vibration need to be evaluated for each application and appropriate safety measures taken when needed. Evaluation of exposure
levels should consider the time a tool is switched OFF and not in use. This may significantly reduce the exposure level over the total working period.