Instructions / Assembly

Figure 7 – Cable Connections
3' (90 cm) and 6' (180 cm) cable extensions are
available to increase the length of your camera
cable up to 30 feet (9 m). To install an extension,
first remove the camera head cable from the
display unit by loosening the knurled knob.
Connect the extension to the handheld as de-
scribed above (Figure 7). Connect the keyed
end of the camera head cable to the slotted end
of the extension and finger tighten the knurled
knob to hold the connection in place.
Installing Accessories
The three included accessories, (Hook, Mag -
net, Mirror) all attach to the imager head the
same way.
Figure 8 – Installing an Accessory
To connect, hold the imager head as shown in
Figure 8. Slip the semicircle end of the acces-
sory over the flats of the imager head. Then ro-
tate the accessory a 1/4 turn to retain.
Installing SD™ Card
Open the left side port cover (Figure 4) to ac-
cess the SD card slot. Insert the SD card into
the slot making sure the contacts are facing to-
wards you and the angled portion of the card is
facing down (Figure 9). SD cards can only be
installed one way do not force. When an SD
card is installed, a small SD card icon will ap-
pear in the upper left hand portion of the
screen, along with the number of images or
length of video that can be stored on the SD
card.
Changing/Installing Batteries
The micro CA-350 is supplied without the bat-
tery installed. If the battery indicator displays
, the battery needs to be recharged. Re -
move the battery prior to storage.
1. Squeeze the battery tabs (See Figure 5)
and pull to remove battery.
Figure 5 – Removing/Installing Battery
2. Insert contact end of battery into the in-
spection tool, as shown in Figure 5.
Powering with the AC Adapter
The micro CA-350 Inspection Camera can al -
so be powered using the supplied AC Adapter.
1. Open the right side port cover (Figure 3).
2. With dry hands, plug the AC adapter into
the outlet.
3. Insert the AC adapter barrel plug into the
port marked “DC 12V”.
Figure 6 – Powering the Unit with AC Adapter
Installing the Imager Head
Cable or Extension Cables
To use the micro CA-350 Inspection Cam er a,
the imager head cable must be connected to
the handheld display unit. To connect the
cable to the handheld display unit, make sure
the camera socket key and display unit socket
slot (Figure 7) are properly aligned. Once they
are aligned, finger tighten the knurled knob to
hold the connection in place.
7
micro CA-350 Inspection Camera
Accessory
1/4 Turn
Flats