Material Safety Data Sheet

Product Name : RIDGID Rechargeable Lithium Ion Batteries, RB-1225R (United States)
6 Rev. A
- OSHA Permissible Exposure
Limits (PEL) - 1 mg/m3 (TWA).
For Nickel, Elemental / Metal:
- ACGIH Threshold Limit Value
(TLV) -
1.5 mg/m3 (TWA), A5 - Not
suspected as a human carcinogen.
For Nickel, Insoluble Compounds,
as Ni:
- ACGIH Threshold Limit Value
(TLV) -
0.2 mg/m3 (TWA), A1 - Confirmed
human carcinogen
Carbon
R36/37/38
, R36/37,
R20, R10
S22, S24/25
F (Highly
Flammable)
Xn (Harmful)
Xi (Irritant)
Airborne Exposure Limits:
- OSHA Permissible Exposure
Limits (PELs):
activated carbon (graphite,
synthetic): Total particulate = 15
mg/m3
Aluminium
foil
R17, R15,
R36/38,
R10, R67,
R65, R62,
R51/53,
R48/20,
R38, R11
S7/8, S43,
S26, S62,
S61,
S36/37,
S33, S29,
S16, S9
F (Highly
Flammable)
Xn (Harmful)
Xi (Irritant)
Airborne Exposure Limits:
-OSHA Permissible Exposure Limit
(PEL):
15 mg/m3 (TWA) total dust and 5
mg/m3
(TWA)
respirable fraction for Aluminum
metal as Al
-ACGIH Threshold Limit Value
(TLV):
10 mg/m3 (TWA) Aluminum metal
dusts
Copper foil
R11, R36,
R37, R38
S5, S26,
S16, S61,
S36/37
F (Highly
Flammable)
N (Dangerous
for the
environment)
Xn (Harmful)
Xi (Irritant)
Copper Dust and Mists, as Cu:
- OSHA Permissible Exposure Limit
(PEL) -
1 mg/m3 (TWA)
- ACGIH Threshold Limit Value
(TLV) -
1 mg/m3 (TWA)