Use and Care Manual

9 – English
OPERATION
USING THE SELECTABLE TRIGGER
See Figures 7 - 9, page 14.
WARNING:
Never wedge or hold back the workpiece contact
mechanism during operation of the tool. Doing so
could result in possible serious injury.
This tool is shipped from the factory with a selectable trigger
set in the Single Sequential Actuation mode. The select-
able trigger can also be set for Contact Actuation mode.
SINGLE SEQUENTIAL ACTUATION MODE
Single sequential actuation provides the most accurate
fastener placement.
Disconnect the tool from the air supply.
Depress the actuation mode button.
Rotate the selector to position ( ).
Release the actuation mode button.
NOTE: The actuation mode selector is spring loaded and
held in position by locking tab to prevent movement during
operation.
WARNING:
The nailer will not function properly if the selector
is not securely seated in either position ( ) or
( ). Always assure the selector is seated properly
to avoid an unexpected fastener discharge and
possible serious personal injury.
Reconnect the tool to the air supply.
Grip the tool firmly to maintain control. Position the
workpiece contact onto the work surface.
Push the tool against the work surface to depress the
workpiece contact.
Squeeze the trigger to drive a fastener.
Allow the tool to recoil away from the work surface as the
fastener is driven.
Always remove your finger from the trigger when the
desired number of nails has been driven.
CONTACT ACTUATION MODE
Contact actuation allows very fast repetitive fastener placement.
Disconnect the tool from the air supply.
Depress the actuation mode button.
Rotate the selector to Position ( ).
Release the actuation mode button.
NOTE: The actuation mode selector is spring loaded and
held in position by locking tab to prevent movement during
operation.
Reconnect the tool to the air supply.
Grip the tool firmly to maintain control.
Squeeze and hold the trigger. Push the tool against the
work surface to depress the workpiece contact and drive
a fastener.
Allow the tool to recoil away from the work surface as the
fastener is driven.
Always remove your finger from the trigger when the
desired number of nails has been driven.
NOTE: In Contact Actuation Mode, the tool may also be
operated by depressing the workpiece contact against the
surface and squeezing the trigger.
WARNING:
During normal use the tool will recoil immediately
after driving a fastener. This is a normal function
of the tool. Do not attempt to prevent the recoil
by holding the nailer against the work. Restriction
to the recoil can result in a second fastener being
driven from the nailer. Grip the handle firmly, let
the tool do the work, and do not place second
hand on top of tool or near exhaust at any time.
Failure to heed this warning can result in serious
personal injury.
SETTING THE AIR PRESSURE
The amount of air pressure required will depend on the size
of the nail and the workpiece material.
Begin testing the depth of drive by driving a test nail into
the same type of workpiece material used for the actual job.
Drive a test nail with the air pressure set at 90-95 psi. Raise
or lower the air pressure to find the lowest setting that will
perform the job with consistent results.
It may be possible to achieve the desired depth with air
pressure adjustments alone. If finer adjustments are needed,
use the drive depth adjustment on the tool.
DEPTH-OF-DRIVE ADJUSTMENT
See Figure 10, page 14.
The depth-of-drive of the nail may be adjusted. It is advis-
able to test the depth on a scrap workpiece to determine
the required depth for the application.
To determine depth-of-drive, first adjust the air pressure
and drive a test nail. To achieve the desired depth, use the
depth-of-drive adjustment on the tool.
Disconnect the tool from the air supply.
Turn the depth selector left or right to change the driving
depth.
Reconnect the tool to the air supply.