METHOD 3 PEDESTAL MOUNT
Secure the MOUNTING FLANGE to MOUNTING PEDESTAL using the hardware provided with the pedestal.
Secure burner to MOUNTING FLANGE as in METHOD 1, item A, C and D.
NOTE: It is suggested that the pedestal be anchored in position on the floor by installing brackets over the
pedestal tube and securing brackets to the floor.
WARNING: WHEN THE COMBUSTION CHAMBER IS LINED WITH A
REFRACTORY MATERIAL, IT IS IMPERATIVE THAT THE END CONE NOT
PROTRUDE INTO THE CHAMBER AREA, AS EXCESSIVE HEAT AT BURNER
SHUT DOWN MAY DAMAGE THE END CONE.
INTERNAL FACTORY WIRING
M
1 2 3 4 5 6 7 8
9
101112
LN
AUX
RIELLO 40 F SERIES OIL BURNERS EQUIPPED
WITH AN ELECTRONIC AIR SHUTTER
INTERNAL FACTORY WIRING
CAPACITOR
PUMP VALVE
(COIL)
SEE FIELD
WIRING
LEGEND:
(A) BROWN
(B) WHITE
(C) BLUE
(D) BLACK
(6) 120V SOURCE ACTIVATES SHUTTER OPEN
(11) MOTOR LEAD 120V SOURCE
( ) 120V CONTROL LOCK OUT ALARM TERMINAL
(AUX) CONSTANT 120V AUXILIARY TERMINAL ~ ELECTRONIC AIR SHUTTER