RIELLO ELETTRONICA N.01.
The Riello Elettronica group UPS product range Page 2 IT Range Page 5 Page 4 Plug Dialog UPS Page 6 Win Dialog Plus UPS Page 8 Net Dialog UPS Page 10 Dialog Active UPS Page 12 Dialog Plus UPS Page 14 NETWORK Range Page 17 Dialog Dual UPS Page 18 Power Dialog Plus UPS Page 21 Multi Dialog UPS Page 23 NET-TEL Range Page 27 Dialog Active Rack UPS Page 28 Dialog Plus Rack UPS Page 30 Multi Switch - Intelligent Transfer Switch Page 32 Sinux Inverter Page 34 INDUSTRY Range Page 3
The RIELLO ELETTRONICA group The Riello Elettronica group was formed in the mid 1990s through the strategic acquisition of leading-edge companies operating within the following markets: • Data Processing and IT • Small Office/Home Office (SoHo) • Telecommunications • Industrial manufacturing • Security – emergency lighting, CCTV and alarm systems • Hospital and Medical SOME FACTS AND FIGURES ABOUT THE GROUP 77 70 70 14 14 years have passed since the “power” business was launched (with 30 years’ specific Un
In 2005 RIELLO UPS delivered over 627MVA of UPS – enough to power every electrical appliance in a major city the size of Milan. installed power KVA INSTALLED POWER 627,713 503,091 382,464 258,108 291,826 205,045 2000 2001 2002 2003 2004 2005 years QUALITY POLICY RIELLO UPS is ISO 9001:2000 certified. Over the years, quality has become engrained in the RIELLO UPS culture and plays an active role in determining product quality and delivering fast, effective customer service levels.
UPS product range UPS SELECTION TABLE Industrial processes e-Business (Server Farms, ISP/ASP/POP) Telecommunication voice and data systems Emergency applications (lights/alarms) Electro-medical devices Cash registers Industrial PLCs Data Centers Electronic Point Of Sale (EPOS) Servers Workstations Local Area Networks (LAN) Small computer networks Personal computers PDG IT RANGE For smaller ICT applications (including home PCs and SOHO - Small Office/Home Office systems) and office voice and data networks r
IT Range Plug Dialog UPS Page 6 Win Dialog Plus UPS Page 8 Net Dialog UPS Page 10 Dialog Active UPS Page 12 Dialog Plus UPS Page 14 5
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes PLUG DIALOG 350-550 VA IT Range PLUG DIALOG single-phase LOAD CONFIGURATOR Load type Personal computer Power (VA)* 250 LCD Monitor 70 15” Monitor 150 Scanner, printer 200
MODELS PDG 400 PDG 600 POWER 350VA/225W 550VA/335W INPUT Rated voltage 230 Vac Voltage range 188-262 Vac Frequency 50/60 Hz OUTPUT 230 Vac Frequency on battery operation 50 or 60 Hz Waveform from battery/inverter Pseudo sinewave BATTERIES Type VRLA AGM Maintenance-free lead-acid Recharge time 6-8 h ENVIRONMENTAL Weight (kg) 3 Dimensions (hwd) (mm) 3.1 88x120x320 Tel.
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes WIN DIALOG PLUS 400-650 VA IT Range WIN DIALOG PLUS single-phase CHARACTERISTICS • Mains power supply stabilisation and filtering (with AVR and filters for atmospheric disturbance s
MODELS WD 40 WP 40 WP 55 WP 65 POWER 400VA/240W 400VA/240W 550VA/330W 650VA/400W INPUT Rated voltage 220-240 Vac Voltage range 230 Vac (+20/-26%) Frequency 50/60 Hz auto sensing Voltage on mains operation 230 Vac (-8%, +10%) Voltage on battery operation 230 Vac (+/-5%) Frequency on battery operation 50 or 60 Hz (+/- 0.5%) Waveform from battery/inverter Pseudo sinewave BATTERIES Type VRLA AGM Maintenance-free lead-acid Recharge time 6-8 h ENVIRONMENTAL Weight (kg) 5.
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system NET DIALOG Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes 800-2000 VA IT Range NET DIALOG single-phase 10 The NET DIALOG series includes the 800-2000VA models and uses digital technology.
MODELS ND 80 ND 100 ND 150 ND 200 POWER 800VA/480W 1000VA/600W 1500VA/900W 2000VA/1200W INPUT Rated voltage 220-230-240 Vac Voltage range 230 Vac (±25%) Frequency 50/60 Hz auto sensing OUTPUT Voltage on mains operation 230 Vac (-8%, +10%) Voltage on battery operation 230 Vac (+/- 5%) 50 or 60 Hz (+/- 0.5%) Transfer time 2 ms Waveform from battery/inverter Pseudo sinewave BATTERIES Type VRLA AGM Maintenance-free lead-acid Recharge time 4-6 h ENVIRONMENTAL Weight (kg) 14 14.
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes DIALOG ACTIVE 500-2000 VA IT Range DIALOG ACTIVE single-phase 12 The DIALOG ACTIVE series includes the 500-750-10001500-2000VA models and uses digital technology.
MODELS DA 50 DA 75 DA 100 DA 150 DA 200 POWER 500VA/335W 750VA/500W 1000VA/670W 1500VA/1000W 2000VA/1340W INPUT Rated voltage 230 Vac Voltage range 230 Vac (-25%, +21%) Frequency 50/60 Hz auto sensing Frequency range +/- 5Hz OUTPUT 230 Vac Voltage on mains operation 230 Vac (-15%, +11%) Frequency 50 - 60 Hz auto sensing Voltage on battery operation DIALOG ACTIVE Rated voltage 230 Vac (+/-5%) Waveform Sinewave Distortion <2% BATTERIES VRLA AGM Maintenance-free lead-acid Rech
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes DIALOG PLUS 700-3000 VA IT Range DIALOG PLUS single-phase The DIALOG PLUS series includes the 700-1000-15002000-3000VA models and uses double conversion technology (VFI).
MODELS DLP 70 DLP 100 DLP100ER DLP 150 POWER 700VA/490W 1000VA/700W 1500VA/1050W DLP 200 DLP200ER DLP 300 DLP300ER 2000VA/1400W 3000VA/2100W INPUT Rated voltage 220 - 230 - 240 Vac 110V up to 60% of load / 120V from 60% to 70% of load 140V from 70 to 80% of load / 160V from 80% to 100% of load Minimum voltage range Maximum voltage 300 Vac 50/60 Hz ± 5Hz Power factor > 0.
16
NETWORK Range Dialog Dual UPS Page 18 Power Dialog Plus UPS Page 21 Multi Dialog UPS Page 23 17
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Telecommuni- e-Business Emergency cation devices (Server Farms, devices ISP/ASP/POP) (lights/alarms) Industrial processes DIALOG DUAL 3,3 - 10 kVA NETWORK Range DIALOG DUAL single/single-phase and three/single-phase 18 DIALOG DUAL is the best solution for protecting medium sized networking applicat
SELECTABLE OPERATING MODES • On line • Economy Mode: selects Line Interactive VI technology to power non-critical loads from mains and achieve up to 98% operating efficiency • Smart Active Mode: the UPS selects automatically whether to operate in On-line VFI technology - full system protection or Line Interactive VI mode depending on the stability of the mains supply • Emergency: the UPS can be programmed to work only when the mains fails - suitable for emergency lighting • Frequency conversion 50 or 60Hz GU
MODELS DLD 330 DLD 400 DLD 500 DLD 600 DLD 800 * DLD 1000 * POWER 3300VA 2300W 4000VA 2400W 5000VA 3500W 6000VA 4200W 8000VA 5600W 10000VA 7000W INPUT Rated voltage Minimum voltage Rated frequency Power factor NETWORK Range DIALOG DUAL Current distortion BY PASS Voltage range Frequency range BATTERIES Recharge time OUTPUT Rated voltage Static variation Dynamic variation Wave form Voltage distortion with linear load Voltage distortion with non-linear load Frequency Crest factor OVERLOAD CAPAC
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes POWER DIALOG PLUS single/single-phase and three/single-phase HIGH RELIABILITY • Full microprocessor control with no-break static and manual bypass.
NETWORK Range POWER DIALOG PLUS MODELS PWP 650 PWP 800 PWP 1000 POWER 6500VA/4600W 8000VA/5600W 10000VA/7000W INPUT Rated voltage Minimum voltage without battery intervention Rated frequency BY PASS Voltage range Frequency range BATTERIES Recharge time OUTPUT Rated voltage Static variation Dynamic variation Wave form Voltage distortion with linear load Voltage distortion with non-linear load Frequency Crest factor OVERLOAD CAPACITY 100% < Load < 125% 125% ≤ Load < 150% Load ≥ 150% ENVIRONMENTAL Wei
Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) MULTI DIALOG MDM / MDT MULTI DIALOG provides maximum protection for critical data processing networks and security applications, thanks to its advanced design, selectable operating modes and communications capabilities.
NETWORK Range MULTI DIALOG MDM/MDT LOW POWER CONSUMPTION • On-line Mode: up to 92% efficiency can be achieved due to the use of IGBT technology, increasing to 98% in one of the other operating modes. • Economy Mode: uses Line Interactive (VI) technology to power less critical loads from the mains supply for certain periods • Smart Active: if the mains supply is out of range, the UPS will power the load from the inverter as an On-line UPS.
MDM MODELS MDM 10 - AF MDM 15 - AF MDM 20 - AF INPUT Rated voltage 230 Vac single-phase or 400 Vac three-phase + N ± 20% Frequency range 45 ÷ 65 Hz Power factor >0.
MDT MODELS MDT10 - AF MDT15 - AF MDT20 - AF MDT30 - AF MDT40 - AF MDT60 - AF MDT80 - AF INPUT Rated voltage 400 Vac three-phase + N NETWORK Range MULTI DIALOG MDM/MDT Voltage range ± 20% Frequency range 45 ÷ 65 Hz Power factor >0.
NET-TEL Range Dialog Active Rack UPS Page 28 Dialog Plus RackUPS Page 30 Multi Switch - Intelligent Transfer Switch Page 32 Sinux Inverter Page 34 27
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes DIALOG ACTIVE RACK 500 - 2000 VA NET-TEL Range DIALOG ACTIVE RACK single-phase 28 For advanced communication and outstanding performance (including Power Share and a true SINEWAV
MODELS DAR 50 DAR 75 DAR 100 DAR 150 DAR 200 POWER 500VA / 335W 750VA / 500W 1000VA / 670W 1500VA / 1000W 2000VA / 1340W Rated voltage 220 ÷ 240 Vac Voltage range 220 ÷ 240 Vac (-25%, +21%) Frequency 50/60 Hz auto sensing ± 5Hz OUTPUT Rated voltage 230 Vac ± 2% Voltage on mains operation automatically corrects output voltage from -15% to +15% with input fluctuation within ±25% Frequency 50 - 60 Hz auto sensing Voltage on battery operation 230 Vac (± 5%) Waveform Sinewave with disto
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes DIALOG PLUS RACK 700 - 3000 VA NET-TEL Range DIALOG PLUS RACK single-phase For outstanding power protection and communication DIALOG PLUS RACK is the best solution for sensitive a
DLPR 100 DLPR100 ER DLPR 150 POWER 700VA / 490W 1000VA / 700W 1500VA / 1050W INPUT Rated voltage Minimum input range Maximum input range Rated frequency Rated current (A) Power factor BY PASS Voltage tolerance Frequency tolerance BATTERIES Type Recharge time OUTPUT Rated voltage Waveform Voltage distortion Frequency Frequency tolerance Crest factor (Ipeak/Irms) Overload 2.
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes NET-TEL Range MULTI SWITCH MULTI SWITCH Output 1 Max 4 A Output 2 Max 4 A Output 3 Max 4 A Input 1 Input 2 Output 4 Max 4 A Output 5 Max 4 A Output 6 Max 4 A Multi-SWITCH i
MODELS MSW (2 input - 8 output) POWER 8x4A output sockets INPUT Input voltage 180 - 276 Vac Rated frequency 50/60 Hz Maximum load for each input (A) 16 Input sockets 2 IEC 320 (16A) OUTPUT selection of one of the two input sources Maximum load for each output (A) 4 Output sockets 8 IEC 320 10A ENVIRONMENTAL Weight (kg) 10 Dimensions (hwd) (mm) 2Ux19”x360 Operating temperature O °C - 40 °C Relative humidity < 95% non condensing Protection Overcurrent - overvoltage - undervoltage - b
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes NET-TEL Range SINUX SINUX INVERTERS Sinux is a range of 12/23/48/110 Vdc inverters with a 230 Vac 50Hz sinewave output.
MODELS POWER (W) INPUT Rated voltage OUTPUT Voltage range ENVIRONMENTAL Output current (A) Overload (W) for 5” Weight (kg) Dimensions (hwd) (mm) AVAILABLE OPTIONS By-pass LCD Display Remote contacts • • • • • • • • • • • • • • SINUX INVERTERS S12 (12 Vdc input) S12 120 115 0,5 300 13 S12 160 161 0,7 400 15 S12 350 345 1,5 600 30 S12 460 460 2 800 32 S12 580 575 2,5 1000 35 S12 690 690 3 1200 40 S12 800 805 3,5 1400 45 0,13 50 3 12 V 10,2 - 18
36
INDUSTRY Range Master Plus UPS Page 38 Master Dialog 12 RT UPS Page 41 Master Dialog RM/RT UPS Page 46 37
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes MASTER PLUS 100 - 200 kVA INDUSTRY Range MASTER PLUS three-phase/three-phase MINIMUM INPACT ON SUPPLIES - EASY SOURCE Master Plus technology removes the problems of over sizing u
Traditionally, when a mains supply is present the UPS charges its batteries. Battery power is used for the inverter should the input supply fail. Efficient battery management and care is therefore essential to the overall performance of the UPS in an emergency.
MODELS POWER (kVA) MP 100 MP 120 MP 160 MP 200 100 120 160 200 INPUT Nominal voltage 380 - 400 - 415 Vac three-phasee Voltage tolerance 400 V ± 20% INDUSTRY Range MASTER PLUS Frequency 45 ÷ 65 Hz Power factor >0.
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes MASTER DIALOG 12RT three-phase/three-phase HIGH RELIABILITY • Extremely high short-circuit current to ensure compatibility with the most difficult transformer applications (lighting,
INDUSTRY Range MASTER DIALOG 12RT OTHER CHARACTERISTICS • reliable, filtered, stabilised and regulated sinewave output (double conversion on-line technology VFI according to EN62040-3 specifications) with filters for atmospheric disturbance suppression • 0.
NO-BREAK POWER ARCHITECTURES The Master DIALOG range features a wide range of modules and configurations that can be manufactured into one complete system to solve your power problems. Each system is there- fore unique and we ask that you consult our engineers for your specific application. Some typical configurations are illustrated below: Mains UPS8 Battery UPS3... Battery UPS2 Battery UPS1 Mains INDUSTRY Range Mains MASTER DIALOG 12RT Bypass mains Maintenance Bypass Cabinet Load 1.
Bypass 1 UPS2B UPS1B Battery Battery UPS2A Battery Mains Mains Mains UPS1A Bypass 2 Battery Mains System B INDUSTRY Range MASTER DIALOG 12RT System A PSJ Load 1 Load 2 3. Dynamic dual bus configuration Mains UPS2B Battery Battery UPS1B UPS2A UPS1A Bypass 2 Mains Mains Mains Battery System B Bypass 1 Battery System A UGS Sinchroniser Static Transfer SWITCH Load 3 Load 1 Static Transfer SWITCH Load 4 4.
12RT 250 12RT 300 12RT 400 12RT 500 12RT 600 12RT 800 250 300 400 500 600 800 INPUT Rated voltage (V) Voltage range Frequency range Total harmonic distortion BY PASS Rated voltage (V) Permitted voltage range Rated frequency Permitted frequency range Standard features BATTERIES Type Maximum recharge current (A) RECTIFIER OUTPUT Maintenance voltage Ripple INVERTER OUTPUT Rated power (kVA) Rated power (kW) Number of phases Rated voltage (V) Rated current (A) Crest factor (Ipeak/Irms) 380-400-415 V
Personal computers Small computers network Local Area Networks (LAN) Workstations Servers EPOS (Electro- Data Centers nic Point Of Sales) system Industrial PLCs Cash registers Electromedical devices Emergency Telecommuni- e-Business devices cation devices (Server Farms, (lights/alarms) ISP/ASP/POP) Industrial processes MASTER DIALOG RM/RT INDUSTRY Range MASTER DIALOG RM/RT RM 8-100 kVA three-phase/single-phase 46 RT 10-80 kVA three-phase/three-phase HIGH RELIABILITY • Extremely high short-circu
• Distortion of the input current <5% in the MASTER DIALOG “CLEAN” version which lets you save on sizing of the power supply source (transformer or generator set) MAXIMUM BATTERY CARE • battery deep discharge protection and temperature compensating charger • built-in automatic and manual battery test feature SIMPLE TO INSTALL OTHER CARACTERISTICS • Reliable, filtered, stabilised and regulated sinewave output (double conversion on-line technology VFI according to IEC62040-3 specifications) with filters for a
RM MODELS RM 8 RM 10 RM 15 RM 20 RM 30 RM 40 RM60 RM 80 RM 100 POWER (kVA) 8 10 15 20 30 40 60 80 100 INPUT Rated voltage (V) 400 Vac three-phase INDUSTRY Range MASTER DIALOG RM/RT Voltage range ± 20% Frequency range 45 ÷ 65 Hz Power factor > 0.
RT MODELS RT 10 RT 15 RT 20 RT 30 RT 40 RT 60 RT 80 POWER (kVA) 10 15 20 30 40 60 80 INPUT Rated voltage (V) 400 Vac three-phase ± 20% Frequency range 45 ÷ 65 Hz Power factor > 0.
SOFTWARE and ACCESSORIES Compatibility table Page 52 PowerShield2 Page 53 PowerNetGuard Page 54 Netman 101/102 Plus Page 55 Multicom 301/302 Page 55 Multicom 351/352 Page 55 Multicom 362 Page 56 Multicom 372 Page 56 Multicom 382 Page 56 Multi I/O Page 57 USB Converter Page 57 Multifunction I/O Page 57 Profibus Converter Page 58 AS400 and i-Series interface kit Page 58 Multi Pass 16 and 16-R Page 58 51
Range of accessories COMPATIBILITY TABLE Communication ports Standard fittings Software and optiional accessories Characteristics Interface devices Communication Kit PowerNetGuard • • • • • • • • • • • • • Fernservice (TeleNetGuard) AS/400 Kit • Multifunction I/O • Multi I/O 1 MultiCOM 382 NET DIALOG MultiCOM 372 • MultiCOM 362 • MultiCOM 302 • MultiCOM 301 • MultiCOM 352 • MultiCOM 351 • NetMan 102 plus • NetMan 101 plus • 1 PowerShield2 • SLOT 1 PLUG DIALOG
POWERSHIELD2 Communication software CHARACTERISTICS • Sequential and priority-based shutdown: PowerShield² provides unattended shut-down of single and networked PCs, saving any active work and the most widely used applications Windows.
POWERNETGUARD Supervision software Software and Accessories PowerNETGuard software centralises UPS management using network interface (SNMP) communications. It is ideal for Data Centre managers and medium to large sized networks. PowerNETGuard uses the RFC1628 standard Management Information Base (MIB) and ensures standardised UPS management wherever they are located.
NETMAN 101/102 Plus Network agent The Netman Plus network agent allows UPS management across a LAN using any of the main network communication protocols - TCP/IP, HTTP and network interface (SNMP). Netman Plus enabled UPS integrate easily into medium and large sized networks and provide reliable communications between the UPS and management systems employed.
MULTICOM 362 Serial / USB port MultiCOM 362 provides a UPS with an additional RS232 serial interface or USB port. The USB port allows the UPS to communicate with Apple Macintosh computers as well as Windows and Linux operating systems. CHARACTERISTICS Software and Accessories • compatible with USB 1 or 2 • compatible with PowerShield². MULTICOM 372 Serial / ESD port MultiCOM 372 provides a UPS with an additional RS232 serial interface port.
MULTI I/O Protocol converter Multi I/O has configurable input and output signal contacts to allow UPS integration with control systems. It can be used to connect two devices to a single UPS serial communication port. It can also communicate using the MODBUS/JBUS protocol on RS485 lines. CHARACTERISTICS USB CONVERTER USB serial converter The RS232-USB converter allows UPS without a USB port to connect to Macintosh, Windows and Linux PCs with this type of port.
PROFIBUS CONVERTER Protocol converter The Profibus Dp Gateway is an accessory with which you can connect a UPS to a Profibus DP network. With this device management and monitoring of the UPS can be integrated in a control system based on one of the field buses most widely used in industry for communication between control/automation systems and distributed I/O. CHARACTERISTICS Software and Accessories • • • • • PROFIBUS DP-V1 Protocol. PROFIBUS DP-V1 Protocol. Configurable address from 1 to 126.
DIALOG CSS STANDBY POWER SYSTEMS RIELLO UPS uninterruptible power supplies are also designed and built for use in applications such as central supply systems for emergency lighting, security alarms and electro-medical equipment. The CEI 64-8 V2, EN 50171 standards and other guidelines set down the characteristics and performance levels required from such systems.
Diagrams of the various system solutions 1. Always powered 2. Powered from the mains A full range of CSS units, from 700VA to 200kVA. 3. Emergency only 4. Always powered/Emergency only The Dialog CSS range units are comprised of the following blocks: Rectifier: converts the alternating voltage input from the mains power supply or from an alternative source (generator) into direct current voltage.
PRE-SALES CONSULTANCY TEC is the RIELLO UPS pre-sales advisory service. Our TEC (Technical Energy Consultant) experts have been working in the power sector for years, and come from backgrounds with technical experience in industry and power plants. CONSULTANCY ON STANDARDS TEC personnel can provide advice on the relevant standards affecting: • RIELLO UPS product ranges • Batteries • Installation • Applications - such as emergency lighting, security and electro-medical.
TECHNICAL SUPPORT AND SERVICES UPService, our technical assistance facility uses highly trained engineers to provide a reliable and competent technical support and after-sales service. UPService can provide customers with: • a dedicated CALL CENTRE for connection to the UPService organisation. UPService personnel are always available and ready to provide advice and assistance regarding UPS installation, maintenance, fault finding and repair.
RIELLO ELETTRONICA INTERNATIONAL SALES UPS MANUFACTURING s.r.l. Viale Europa, 7 ZAI 37048 S. Pietro di Legnago Verona - ITALY Tel.: +39 0442 635811 Fax: +39 0442 629098 www.riello-ups.com riello@riello-ups.com UK RIELLO UPS Ltd Unit 68 - Clywedog Road North Wrexham Industrial Estate - Wrexham LL13 9XN Tel.: +44 (0)1978 729 297 - Fax: +44 (0)1978 729 290 www.riello-ups.co.uk / riello@riello-ups.co.uk FRANCE RIELLO ONDULEURS s.a.r.l.