Datasheet

Emergency stop and safety gate monitoring relays
Printing 11.03.2016
DEVICE
SAFE 2 / SAFE 2.1
Emer
g
enc
y
sto
p
APPLICATIONS
and safety gate monitoring relay
APPROVALS
CE, TÜV, UL, C-UL
CONTACTS
2 normally open safety
LED indicators for status and supply diagnostic
SPECIAL CHARACTERISTICS
With (SAFE 2) and without (SAFE 2.1) start control
LED
Power, channel 1 and channel 2
24 V AC / DC (electronic fuse)
OPERATING VOLTAGE
POWER CONSUMPTION
ca. 2,5 VA / 2,5 W
START UP DELAY / FALLBACK TIME
<50 ms / <30 ms
CONTACT CAPACITY max.
6 A, 250 V AC, 24 V DC
CONTACT CAPACITY min. at 24 V DC (*)
6 mA
SIMULTANEITY
ENVIRONMENTAL TEMPERATURE
-25°C to + 55°C
SWITCHING CAPACITY
1500 VA (resistive load)
CONTACT SECURITY
6,3 A quick acting or 4 A time lag
OPERATING MODE
(*) We offer all devices who have a CONTACT CAPACITY of
min. 100 mA at 24 V DC with hard gold-plated contacts.
In this way the CONTACT CAPACITY of min. 100 mA is only 4 mA.
Please ask our sales team!
CONNECTION DIAGRAM
A supply voltage must be applied to terminals A1 and A2. Power LED
illuminates and 24 V DC is available at terminal S11. Terminals S12 and S22
must be connected according to the application example selected to meet the
application requirements. To start the unit terminals S33 and S34 must be
bridged with a normally open contact. The unit works if you close this contact.
At this time the contacts 13-14 and 23-24 are closed. The LEDs channel 1 and
channel 2 illuminate. In series to this start button an external contactor can be
controlled
.
S34 S33
S11
S12
S21 S22
Not-Halt
E-Stop
Start
FUNCTION CIRCUIT DIAGRAM
Überwachungslogik /
control logic
~ ~
S21
~
~
+
=
K1
A1
(+)
elektr.
Sicherung /
electronic
fuse
A2
(-)
S11 S12
14
K2
K2
24
K1
S34S22
S33 13 23
Certifications according to
Safety relevant substance data
Depending on wiring (only max. achievable values are given)
EN ISO 13849-1: PLe, Cat. 4
MTTFd: 69 years / high, DC: 99% / high,
CCF: achieved