Datasheet

Emergency stop and safety gate monitoring relays
Printing 11.03.2016
DEVICE
SAFE 4.3 eco
Safet
y
g
ate monitorin
g
rela
y,
Safet
y
ma
g
netic switch
APPLICATIONS
Suitable for release button with reed contact outputs
APPROVALS
CE, TÜV, UL, C-UL
CONTACTS
3 normally open safety, 1 normally auxiliary closed
LED indicators for status and supply diagnostic
SPECIAL CHARACTERISTICS
Opposite polarity between channels
With and without start control (selectable)
LED
Power, channel 1 and channel 2
24 V AC / DC (electronic fuse)
OPERATING VOLTAGE
115, 230 V AC (with galvanic disconnection / transformer)
POWER CONSUMPTION
24 V DC: 1,5 W / AC: 3,6 VA
START UP DELAY / FALLBACK TIME
200 ms / <10 ms ready after time delay <0,5 s
CONTACT CAPACITY max.
5 A, 240 V AC, 24 V AC / DC
CONTACT CAPACITY min. at 24 V DC (*)
10 mA
SIMULTANEITY
ENVIRONMENTAL TEMPERATURE
-25°C to + 55°C
SWITCHING CAPACITY
1200 VA (resistive load)
CONTACT SECURITY
6,3 A quick acting or 4 A time lag
OPERATING MODE
(*) We offer all devices who have a CONTACT CAPACITY of
min. 100 mA at 24 V DC with hard gold-plated contacts.
In this way the CONTACT CAPACITY of min. 100 mA is only 4 mA.
Please ask our sales team!
CONNECTION DIAGRAM
A supply voltage must be applied at terminals A1 and A2. The power LED
lights. Terminals S11, S12, S21 and S22 have to be wired up as shown in
the application examples. To start the unit, follow the examples
described in the start applications section. In series to the start-button an
external contactor can be controlled (see application example). After
activation the contacts 13-14, 23-24 and 33-34 are closed, contact 41-42 is
opened. The LEDs channel 1 and channel 2 are lit.
For version with detachable clamps (screw - or cage clamps) ...
please ask our sales team!
Start
S21 S22
S11 S12S34
U
B
A1
A2
Safety gate with monitored start button and antivalent switching safety
gate contacts.
FUNCTION CIRCUIT DIAGRAM
S12
monitoring logic
~ ~
~
~
+
=
K1
electr. fuse
transformer
A1
(+)
A2
(-)
S34
S33 S11
14
K2
K2
3424 42
13
K1
S22S21
3323 41
Certifications according to
Safety relevant substance data
Depending on wiring (only max. achievable values are given)
EN ISO 13849-1 / DIN EN 61508 / DIN EN 62061: PLe, Cat. 4 / SIL3
MTTFd: 910 years / high, DC: 99% / high, CCF: achieved,
PFH: 2,32*10
-9
1
/
h
, SFF: > 99%, HFT: 1

Summary of content (1 pages)