Quick Start Guide

RIGOL
20 DG1000Z Quick Guide
6. To set harmonic amplitude
Press Harmonic Ampl in the harmonic setting menu to set the amplitude of the
2
nd
and 4
th
harmonics.
1) Press SN, use the numeric keyboard to input 2 and press Sure.
2) Press Harmonic Ampl, use the numeric keyboard to input 2 and select
Vpp from the pop-up menu.
3) Set the amplitude of the 4
th
harmonic to 1Vpp according to 1) and 2).
7. To set harmonic phase
Press Harmonic Phase in the harmonic setting menu to set the phase of the
2
nd
and 4
th
harmonics.
1) Press SN, use the numeric keyboard to input 2 and press Sure.
2) Press Harmonic Phase, use the numeric keyboard to input 30 and select °
from the pop-up menu.
3) Set the phase of the 4
th
harmonic to 50° according to 1) and 2).
8. To enable the output
Press Output1 to turn CH1 output on. At this point, the backlight goes on and
the [CH1] connector outputs the fundamental waveform as well as the 2
nd
and
4
th
harmonics.
9. To observe the output waveform
Connect the [CH1] connector to the oscilloscope using BNC cable. The
waveform is as shown in Figure 9.
Figure 8 Harmonics