Term Explanation
Frequency Deviation
The Deviation should be equal to or less than the Carrier Waveform Frequency.
The Sum of the Deviation and the Carrier Frequency should be equal to or less
than maximum frequency of the selected function plus 100 kHz.
For an External Source, the Deviation is controlled by the ± 5V voltage Level of
the Connector connected to the [Modulation In]. +5V adds to the selected
Deviation, lower external voltage generates less deviation, while negative
voltage reduces the modulated signal frequency below the corresponding
carrier’s.