User Manual
Table Of Contents
- Safety Notices
 - The Introduction of DG3000 Series
 - Getting Started
 - Operating Your Generator
 - Application & Examples
- Example 1: To Generate a Sine Wave
 - Example 2: To Generate a Square Wave
 - Example 3: To Generate a Ramp Wave
 - Example 4: To Generate a Pulse Wave
 - Example 5: To Generate a Noise Wave
 - Example 6: To Generate an Arbitrary Waveform
 - Example 7: To Create an Arbitrary Waveform
 - Example 8: To Generate an AM Waveform
 - Example 9: To Generate an FSK Waveform
 - Example 10: To Generate a PWM waveform
 - Example 11: To Generate Linear Sweep
 - Example 12: To Generate a Burst Waveform
 
 - Prompt messages & troubleshooting
 - Specifications
 - Appendix
 - Index
 
RIGOL 
© 2006 RIGOL Technologies, Inc.                                                                                                                       
  User’s Guide for DG3000 Series 
4-13 
FM Frequency upper limit =20kHz   
FM Frequency upper limit is 20 kHz. If the specified FM Frequency is greater than 20 
kHz, the system will adjust the FM Frequency to 20 kHz automatically. 
FM Frequency lower limit = 2mHz 
FM Frequency lower limit is 2mHz. If the specified FM Frequency is less than 2mHz, 
the system will adjust the FM Frequency to 2mHz automatically.   
Deviation plus Carrier cannot exceed maximum 
The sum of the Carrier frequency and the deviation frequency should be less than or 
equal to the selected maximum frequency plus 100 kHz. 
AM Depth upper limit = 120.0% 
The  AM  Depth  upper  limit  is  120.0%.  If  the  specified  AM  Depth  is  greater  than 
120.0%, the system will adjust the AM Depth to 120.0% automatically. 
AM Depth lower limit = 0.0% 
The AM Depth lower limit is 0.0%. If the specified AM Depth is less than 0.0%, the 
system will adjust the AM Depth to 0.0% automatically. 
AM Frequency upper limit = 20kHz 
The AM Frequency upper limit is 20 kHz. If the specified AM Frequency is greater 
than 20 kHz, the system will adjust the AM Frequency to 20 kHz automatically. 
AM Frequency lower limit = 2mHz 
The AM Frequency lower limit is 2mHz. If the specified AM Frequency is less than 
2mHz, the system will adjust the AM Frequency to 2mHz automatically. 
Hop Frequency upper limit = ** 
Different Source types have different Hop Frequency upper limit. If the Carrier is a 
Square or Sine wave, the Hop Frequency upper limit is 120MHz; If the Carrier is a 
Ramp wave, the Hop Frequency upper limit is 1MHz; If the Carrier is an Arb wave, 
the Hop Frequency upper limit is 25MHz. 
Hop Frequency lower limit = 1μHz 
The Hop Frequency lower limit is 1μHz. If the specified Hop Frequency is less than 
1μHz, the system will adjust the Hop Frequency to 1μHz automatically.   
FSK Rate upper limit = 100kHz 
The FSK Rate upper limit is 100KHz. If the specified FSK Rate is greater than 100KHz, 
the system will adjust the FSK Rate to100KHz automatically.   
FSK Rate lower limit = 2mHz   
The FSK Rate lower limit is 2mHz. If the specified FSK Rate is less than 2mHz, the 
system will adjust the FSK Rate to 2mHz automatically. 
Start Frequency upper limit = **   
Different Source types have different Start Frequency upper limit. If the Carrier is a 
Square or Sine wave, the Start Frequency upper limit is 120MHz; if the Carrier is a 
Ramp wave, the Start Frequency upper limit is 1MHz; if the Carrier is an Arb wave, 