User Manual

RIGOL
© 2006 RIGOL Technologies, Inc.
Users Guide for DG3000 Series
2-43
Figure 2-49 Table 2-27 The Menu Explanations of Waveform Sweep (Page 1/2)
Sweep Frequency Setting
Use Start Freq and Stop Freq or Center Freq and Freq Span to set the
range of the frequency. Press the button again to switch between each other.
To Sweep upward, set the Start Frequency lower than the Stop Frequency, or set
a positive frequency interval.
To Sweep downward, set the Start Frequency higher than the Stop Frequency, or
set a negative frequency interval.
Figure 2-50 Table 2-28 The Menu Explanations of Waveform Sweep (Page 2/2)
Function
Menu
Settings
Explanation
Swp Time
Set the Time Span of the Sweep for
which the Frequency changes from the
Start Frequency to Stop Frequency.
Stop Freq
Freq Span
Set the Stop Frequency of the Sweep
Set the Frequency Span of the Sweep
Start Freq
Center Freq
Set the Start Frequency of the Sweep
Set the Center Frequency of the Sweep
Source
Internal
External
Mannal
Choose Internal Source
Choose External Source, use the [Ext
Trig/FSk/Burst] connector in the rear
panel
Choose External Source, set the start
and stop time by hand
Function
Menu
Settings
Explanation
Trig
Off
Set Signal Triggered at Rise Edge
Set Signal Triggered at Fall Edge
Turn off Trigger Setting
Linear
Log
Set the Sweep with linear spacing
Set the Sweep with logarithmic
spacing