Datasheet

5
RIGOL
Mechanical
Dimensions 239 mm(W) x 157 mm(H) x 442 mm(D)
Weight Net weight: 7.58 kg
Power
AC Input (50 Hz~60 Hz) 115 Vac±10%, 230 Vac±10% (max: 250 Vac)
Maximum Input Power <30 VA
Interface
USB Device Interface 1
USB Host Interface 1
LAN Interface 1(optional)
RS232 1
Digital I/O 1(optional)
GPIB
1 ((optional, GPIB extended from the USB-GPIB interface
module)
Environment
Cooling Method Fan Cooled
Operating Temperature 0
~40
Storage Temperature -40
~70
Humidity 5%~80% RH (without condensation)
Altitude Below 2,000 m
Note
[1]
: Data measured after 30-second current sinking at the programming value (applicable to the programming accuracy
in CC mode and CV mode).
Note
[2]
: FS indicates the full scale.
Note
[3]
: The input voltage for the low range in CR mode should be smaller than 8 V.
Note
[4]
: The programming accuracy in CR mode is also determined by the input voltage accuracy.
Note
[5]
: Current slew rate: rising slew rate for 10%~90% of the current (0-maximum current).
Note
[6]
: When the input voltage is greater than 5 V, the maximum current slew rate is 5 A/μs; when the input voltage is greater than 4 V,
the maximum current slew rate is 2.5 A/μs; when the input voltage is greater than 2 V, the maximum current slew rate is 0.1 A/μs.
Note
[7]
: Following a steady 30-minute current sinking, change in current/voltage sinking over 8 hours under constant load, line,
and ambient temperature.
Certication Information
EMC
Complies with the requirements of the following directive and
standards.
EMC Directive 2014/30/EU
EN 61326-1
EN 61000-3-2
EN 61000-3-3
Under following condition.
The maximum length of all connecting cables and wires to
the DL3000 series are less than 3 m.
Safety
Complies with the requirements of the following directive and
standard.
Low Voltage Directive 2014/35/EU
EN 61010-1:2010
IP Degree: IP20
Pollution Degree: PD 2
Over Voltage Category: OVC II
Operation Location: Indoor use only; not for wet condition