RIGOL English Quick Guide 中文 DL3000 Programmable DC Electronic Load Feb. 2017 RIGOL TECHNOLOGIES, INC.
RIGOL Guaranty and Declaration English Copyright © 2017 RIGOL TECHNOLOGIES, INC. All Rights Reserved. Trademark Information RIGOL is a registered trademark of RIGOL TECHNOLOGIES, INC. Publication Number QGJ01100-1110 Notices RIGOL products are covered by P.R.C. and foreign patents, issued and pending. RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at the company’s sole decision.
RIGOL English General Safety Summary 1. 2. 3. 4. 5. 6. Only the exclusive power cord designed for the instrument and authorized for use within the local country could be used. Ensure that the instrument is safely grounded. Observe all terminal ratings. Use proper overvoltage protection. Do not operate without covers. Do not insert objects into the air outlet. 7. 8. 9. 10. 11. 12. 13. 14. 15. Use the proper fuse. Avoid circuit or wire exposure. Do not operate the instrument with suspected failures.
RIGOL Safety Symbols on the Product: Hazardous Voltage Safety Warning DL3000 Quick Guide Protective Earth Terminal English Chassis Ground Test Ground 3
RIGOL English Care and Cleaning Care Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time. Cleaning Clean the instrument regularly according to its operating conditions. 1. Disconnect the instrument from all power sources. 2. Clean the external surfaces of the instrument with a soft cloth dampened with mild detergent or water. When cleaning the LCD, take care to avoid scarifying it.
RIGOL Document Overview English This manual introduces some basic information that you should know when you use DL3000 for the first time. It contains the following contents: out-of-box inspection method, product overview, turn-on checkout, and remote control overview. Tip For the latest version of this manual, download it from RIGOL official website (www.rigol.com).
RIGOL English General Inspection 1. Inspect the packaging If the packaging has been damaged, do not dispose the damaged packaging or cushioning materials until the shipment has been checked for completeness and has passed both electrical and mechanical tests. The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument.
RIGOL Product Overview English DL3000 is a cost-effective programmable DC electronic load with high performance. With a user-friendly interface and superb performance specifications, DL3000 provides various interfaces for remote communication to meet your diversified test requirements. It can be widely used in various industries, such as automotive electronics, aerospace, and fuel cells.
RIGOL English Air Outlet Digital I/O LAN Interface Current Monitoring Output Terminal AC Selector AC Power Cord Connector Fuse Voltage Monitoring Output Terminal Fuse Rating RS232 Interface USB DEVICE Figure 2 Rear Panel Company Logo System Status Icons Function State Actual Input Values Menu Item Figure 3 Main Interface 8 DL3000 Quick Guide
RIGOL Turn-on Checkout English To Connect to Power Supply Two kinds of AC power inputs are supported by DL3000 series electronic load. When the DL3000 series is connected to different power sources, the AC selector setting on its rear panel is different, as shown in Table 1.
RIGOL English To Power on the instrument After the instrument is connected to the power source, press the Power key at the left bottom of the front panel to power on the instrument. When the instrument is turned on, it will undergo a self-test. If the instrument passes the self-test, the welcome interface is displayed; otherwise, self-test failure information will be displayed. At this time, please contact RIGOL distributors.
RIGOL To Use the Built-in Help System English The built-in help system provides help information for any key on the front panel (except parameter input area) and menu keys, which are convenient for you to get the descriptions of the function keys or menus, as shown in Figure 4. Figure 4 Help Information Interface 1. Get the built-in help information Press Help, and then "Help" will be displayed at the top of the interface, being highlighted.
RIGOL English Parameter Setting Method Most parameters can be set by operating the keys on the front panel. The common setting methods are listed below. The setting method for certain parameters is different from the methods below, refer to the relevant chapters of this manual for the further explanation. Method 1: Use the numeric keys 1. In the main interface, press the specified menu key to switch the parameter focus; in the guide interface, use the arrow keys to switch the parameter focus. 2.
RIGOL Remote Control English DL3000 electronic load can be connected to the PC via the USB, LAN, GPIB, or RS232 interface to build communication and realize remote control. The remote control can be realized by using SCPI (Standard Commands for Programmable Instruments) commands. DL3000 electronic load supports two ways of remote control: user-defined programming and PC software (e.g. RIGOL Ultra Sigma). When the instrument is in remote control, the icon is displayed on the interface.