*RCL
Syntax
*RCL <position>
Description
Recalls the state file or timer file stored in the specified location in the internal non-volatile memory of the
power supply.
Parameter
Name Type Range Default
<position> Discrete {1|2|3|4|5|6|7|8|9|10|11|12} --
Remarks
The internal non-volatile memory of DP700 series power supply provides ten storage locations for state
files and two for timer files. They are used to store the state information of the instrument and the
timer parameters, respectively.
<position>:
{1|2|3|4|5|6|7|8|9|10}: indicates the storage location for the state file, which corresponds to
"State1...State10" in the storage and recall interface.
{11|12}: indicates the storage location for the timer file, which corresponds to "Timer1 and Timer2" in
the storage and recall interface.
After the files have been read, the status information of the instrument or the timer parameters will
change accordingly.
If no file is found to be saved in the selected storage location, the command is invalid.
You can also send the
:MEMory[:STATe]:LOAD command to recall the saved state files or timer files
from the internal memory.
Example
*RCL 2 /*Recalls the state file stored in the storage location State2*/
Related Command
:MEMory[:STATe]:LOAD
*RST
Syntax
*RST
Description
Restores the instrument to the default settings (refer to
Appendix A: Default Settings).
Related Command
:SYSTem:ERRor?
*SAV
Syntax
*SAV <position>
Description
Saves the current state or timer parameters of the power supply with the default file names to the specified
location of the internal memory.