User manual

RIGOL Kapitel 5 Technische Daten
5-4 DP800 Benutzerhandbuch
Transient Response Time
Less than 50µs for output voltage to recover to within 15mV following a change in
output current
from full load to half load or vice versa.
Command Processing Time
[2]
<118ms
OVP/OCP
Accuracy ±(Output Percentage+Offset) 0.5%+0.5V/0.5%+0.5A
Voltage Programming Control Speed (1% within the total variation range)
Channel
Rise Fall
Full Load No Load Full Load No Load
DP832
CH1
CH2
CH3
<50ms
<50ms
<15ms
<33ms
<38ms
<14ms
<46ms
<46ms
<24ms
<400ms
<400ms
<100ms
DP831
CH1
CH2
CH3
<18ms
<33ms
<35ms
<17ms
<36ms
<42ms
<20ms
<44ms
<45ms
<200ms
<400ms
<400ms
DP821
CH1
CH2
<110ms
<15ms
<30ms
<15ms
<110ms
<20ms
<800ms
<400ms
DP811 CH1 <45ms <42ms <51ms <1089ms
Temperature Coefficient per
(Output Percentage+Offset)
Channel Voltage Current
DP832
CH1
CH2
CH3
0.01%+5mV
0.01%+5mV
0.01%+2mV
0.01%+2mA
0.01%+2mA
0.01%+2mA
DP831
CH1
CH2
CH3
0.01%+2mV
0.01%+2mV
0.01%+2mV
0.02%+3mA
0.02%+3mA
0.02%+3mA
DP821
CH1
CH2
0.01%+3mV
0.01%+3mV
0.02%+3mA
0.02%+3mA
DP811 CH1 0.01%+3mV 0.02%+3mA