Instructions
RIGOL Chapter 2 Command System
2-94 DS1000Z-E Programming Guide
:MASK Commands
The :MASK commands are used to set and query the pass/fail test parameters.
Command List:
:MASK:ENABle
:MASK:SOURce
:MASK:OPERate
:MASK:MDISplay
:MASK:SOOutput
:MASK:OUTPut
:MASK:X
:MASK:Y
:MASK:CREate
:MASK:PASSed?
:MASK:FAILed?
:MASK:TOTal?
:MASK:RESet
:MASK:ENABle
Syntax :MASK:ENABle <bool>
:MASK:ENABle?
Description Enable or disable the pass/fail test or query the status of the past/fail test.
Parameter
Name
Type
Range
Default
<bool> Bool {{1|ON}|{0|OFF}} 0|OFF
Explanation The pass/fail test is invalid in the following conditions: the horizontal timebase is XY or
ROLL, in the slow sweep mode (namely when the horizontal timebase is YT, the
horizontal timebase is set to 200ms/div or slower) as well as during waveform record.
Return
Format
The query returns 1 or 0.
Example :MASK:ENABle ON /*Enable the pass/fail test*/
:MASK:ENABle? /*The query returns 1*/
:MASK:SOURce
Syntax :MASK:SOURce <source>
:MASK:SOURce?
Description
Set or query the source of the pass/fail test.
Parameter
Name
Type
Range
Default
<source>
Discrete
{CHANnel1|CHANnel2}
CHANnel1