Instructions
Chapter 2 Command System RIGOL
DS1000Z-E Programming Guide 2-105
Format
Example :MEASure:ADISplay ON /*Enable the all measurement function*/
:MEASure:ADISplay? /*The query returns 1*/
:MEASure:AMSource
Syntax :MEASure:AMSource <src>[,<src>[,<src>[,<src>]]]
:MEASure:AMSource?
Description
Set or query the source(s) of the all measurement function.
Parameter
Name
Type
Range
Default
<src>
Discrete
{CHANnel1|CHANnel2|MATH}
CHANnel1
Return
Format
The query returns CHAN1, CHAN2, or MATH. Multiple sources are separated by commas.
Example
:MEASure:AMSource CHANnel1,CHANnel2 /*Set the sources of the all measurement
function to CH1 and CH2*/
:MEASure:AMSource? /*The query returns CHAN1,CHAN2*/
:MEASure:SETup:MAX
Syntax :MEASure:SETup:MAX <value>
:MEASure:SETup:MAX?
Description Set or query the upper limit of the threshold (expressed in the percentage of amplitude) in
time, delay, and phase measurements.
Parameter
Name
Type
Range
Default
<value> Integer 7 to 95 90
Explanation The upper limit, middle point, and lower limit of the threshold (expressed in the
percentage of amplitude) are used to define the time, delay, and phase parameters.
Setting these values will affect the measurement results of the time, delay, and phase
parameters.
Setting the upper limit lower than the middle point will automatically reduce the
middle point to keep it lower than the upper limit.
Return
Format
The query returns an integer between 7 and 95.
Example
:MEASure:SETup:MAX 95 /*Set the upper limit of the threshold to 95%*/
:MEASure:SETup:MAX? /*The query returns 95*/
Related
Commands
:MEASure:SETup:MID
:MEASure:SETup:MIN
:MEASure:ITEM