RIGOL User’s Guide DSA1000&DSA1000A Series Options&Accessories Nov 2011 RIGOL Technologies, Inc.
RIGOL Guaranty and Declaration Copyright © 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered trademark of RIGOL Technologies, Inc. Publication Number UMD01104-1110 Notices RIGOL products are protected by patent law in and outside of P.R.C. RIGOL Technologies, Inc. reserves the right to modify or change parts of or all the specifications and pricing policies at company’s sole decision.
RIGOL Content Guaranty and Declaration .................................................................................. 1 Content ........................................................................................................... 2 DSA1000 Series Options&Accessories ................................................................. 3 DSA1000A Series Options&Accessories ............................................................... 4 Preamplifier ...................................................
RIGOL DSA1000 Series Options&Accessories Name Descriptions Options Preamplifier DSA1030-PA (For DSA1030 only) Advanced Measurement Kit DSA1000-AMK (For DSA1030 only) 3 GHz Tracking Generator DSA1030-TG3 (For DSA1030 only) PC software for DSA Ultra Spectrum* USB-GPIB Interface Converter for Instrument USB-GPIB RF Demo Kit (Transmitter) TX1000 Standard Accessories Power Cord 1 USB Cable 1 Front Panel Cover 1 Quick Guide 1 CDROM 1 (User’s Guide, Programming Guide) Optional Accessories
RIGOL DSA1000A Series Options&Accessories Name Description Options 3 GHz Tracking Generator DSA1030-TG3 PC software for PC Ultra Spectrum* USB to GPIB Interface Converter for Instrument USB-GPIB RF Demo Kit (Transmitter) TX1000* Standard Accessories Power Cord 1 USB Cable 1 Front Panel Cover 1 Quick Guide 1 CDROM 1 (User’s Guide, Programming Guide) Optional Accessories Desk Mount Instrument Arm ARM RF Demo Kit TX1000 DSA Accessories Package DSA Utility Kit* Front Panel Cover DSA1
RIGOL Preamplifier Turning on the preamplifier reduces the displayed average noise level in order to distinguish small signals from the noise when working with small signals. For the instruments supported option DSA1030-PA, pressing the front panel key AMPT, a corresponding menu will appear on the right of the screen. Then, press RF Preamp to turn on or off the preamplifier. An icon will be displayed on the left of the screen when the preamplifier is on.
RIGOL Advanced Measurement Functions Option DSA1000-AMK provides plenty of advanced measurement functions including T-Power (Time domain Power), ACP (Adjacent Channel Power), Chan Pwr (Channel Power), OBW (Occupied Bandwidth), EBW (Emission Bandwidth), C/N Ratio, Harmo Dist (Harmonic Distortion), TOI (Third Order Intermodulation) and Pass/Fail. The measure mode can be Single or Continuous and you can control the measurement status: Restart, Pause or Resume.
RIGOL 2. ACP (Adjacent Channel Power) Measures the power of the main channel and the adjacent channels and calculates the power difference between the main and each of the adjacent channels. When enabled, both the span and resolution bandwidth of the analyzer are adjusted to be smaller automatically. CH Spacing Adj CH BW Main CH BW 3. Chan Pwr (Channel Power) Measures the power and the power density within a specified channel bandwidth.
RIGOL 4. OBW (Occupied Bandwidth) Calculates the power within whole bandwidth by integral operation and works out the occupied bandwidth by this value based on the specified power ratio. The center frequency difference between the measured channel and the analyzer will also be given in the measurement results. 5. EBW (Emission Bandwidth) Measures the bandwidth of the two points at both sides of the max signal when the amplitude of this max signal falls off X dB within the span range.
RIGOL 6. C/N Ratio Measures the power of both the carrier and the noise within specified bandwidth and calculates their ratio. Offset Freq Noise BW Carrier BW 7. Harmo Dist (Harmonic Distortion) Measures each order harmonic power and THD (Total Harmonic Distortion) of carrier. The available range is up to 10 orders. And the fundamental wave amplitude of the carrier must be higher than -50 dBm or else the measurement will be invalid.
RIGOL 8. TOI (Third Order Intermodulation) Measures the parameters of the TOI production generated by two signals which have the same amplitude and similar frequency. The measured results include the frequency and amplitude of the Base Lower, Base Upper, 3rd Order Lower and 3rd Order Upper signals, as well as the Intercept of both the 3rd Order Lower and 3rd Order Upper signals. 9.
RIGOL 3 GHz Tracking Generator When the Tracking Generator (DSA1030-TG3 Option) is on, a signal with the same frequency with the current sweep signal will be outputted from the GEN OUTPUT 50 Ω terminal on the front panel. The power of the signal could be set through the menu. And two working modes, Power Sweep Output and Fixed Power Output, are available. The characteristic of the DUT (Device Under Test) can be acquired by measuring the response of the DUT stimulated by the Tracking Generator.
RIGOL Tracking Generator Specifications Item Condition Value Frequency Range Output Power Output Flatness 12 9 kHz to 3 GHz -20 dBm to 0 dBm, in 1 dB steps 10 MHz to 3 GHz, Reference to 50 MHz ± 3 dB DSA1000&DSA1000A Options&Accessories
RIGOL USB-GPIB Interface Converter By using RIGOL USB-GPIB interface converter, the spectrum analyzer could be connected to a GPIB Bus Controller on PC. That is, the analyzer has been expanded GPIB interface and could finish all sorts of work more easily through GPIB instructions. And the main performance characters are shown below. Enable GPIB control of the analyzer through the USB Host port. GPIB primary address of the analyzer can be assigned through the host instrument (PC).
RIGOL Front Panel Cover The cover is provided to avoid damage to the front panel of the analyzer during transportation. Before putting your analyzer into action, remove the front panel cover by releasing latches at both sides, and sliding in the direction of the arrows as shown in the figure below.
RIGOL Desk Mount Instrument Arm Using an arm, the analyzer could be mounted on the workdesk to save your operation space. The height and angle of the instrument could be adjusted freely to acquire a supreme comfort and efficiency making measurement and observation conveniently. To use the arm, please order the related option. The effects figures of an analyzer installed to an arm are given below.
RIGOL Rack Mount Kit The analyzer could be installed in 19-inch standard machine cabinet, shown below. 1. 16 Kit Parts List No. Name Qty.
RIGOL 2-1 2.
RIGOL 3. Space Requirements for Installation The following requirements must be fulfilled by the machine cabinet in which the instrument is mounted. Dimension of the machine cabinet must be standard 19-inch. At least 6U (266.7mm) space should be provided by the machine cabinet. The depth inside the machine cabinet should not be less than 300 mm. The dimension of the instrument after being installed is shown below.
RIGOL 4. Installation Procedures A PH2 Phillips Screwdriver is recommended. Note that the instrument will be damaged or installed in rack incorrectly if the installation is not proper. Thus, only authorized operators can execute the installation operation. 1) Install the right and left palate: aim the detents of right and left plate at the openings on support board and insert respectively, then fix them using six M4 screws.
RIGOL 3) Fix the instrument: Fix a “Rear Support Bar” and two “Fixed Figure” on the instrument using four M4*8 Screws. Locate the instrument on proper location and then fixed the “Rear Support Bar” and “Fixed Figure” on the left/right board and the Support Board using eight M4*6 Screw. 4) Mount Front Panel: Let the screw holes fitting well together, and aiming the instrument front panel at the opening of the Front Panel of the machine rack and fix them with six M4 screws.
RIGOL 5) Load into machine cabinet: mount the rack with instrument-fixed into a standard 19-inch machine cabinet respectively using four M6 screws and square nuts. 6) Notice: The rack holds a height of 6U, and the holes those in compliance with the arrow direction are the mounting holes for rack.
RIGOL Soft Carrying Bag The bag is designed by RIGOL for utility model measurement instruments. It has reasonable structure as adopting some improvements according to the instrument and practical application. It is in conformity with human engineering and could help you to carry instrument and its accessories easily with comforts and conveniences. Main features 22 Could be held by hand, one-shoulder or shoulders.
RIGOL Held by shoulders Held by Neck&Waist DSA1000&DSA1000A Options&Accessories Carried by Hand 23
RIGOL Other Accessories Accessories along with the instrument are shown below. Note that the pictures here are for your reference only. Some differences may exist. Power Cord USB Cable Quick Guide CDROM* Front Panel Cover *Note: The CD contains User’s Guide. If there are some modifications on it, Please be according to the version on the RIGOL website.