User`s guide

RIGOL Chapter 2 Front Panel Operations
2-62 DSG3000 Users Guide
signal generator will acquire an IP address from 169.254.0.1 to
169.254.255.254 and subnet mask 255.255.0.0 automatically according to
the current network configuration.
Manual-IP
One of the IP address setting methods. Turn on the manual IP and users
can define the IP address of the RF signal generator.
IP
Set the IP address, subnet mask and gateway manually.
a) Press IP Address and use the numeric keyboard to input the desired
IP address.
The format of the IP address is nnn.nnn.nnn.nnn. Wherein, the first
nnn ranges from 1 to 223 (except 127) and the other three range from
0 to 255. You are recommended to ask your network administrator for
an available IP address.
b) Press Sub Mask and use the numeric keyboard to input the desired
subnet mask.
The format of the subnet mask is nnn.nnn.nnn.nnn. Wherein, the
range of the nnn is from 0 to 255. You are recommended to ask your
network administrator for an available subnet mask.
c) Press Gateway and use the numeric keyboard to input the desired
gateway.
The format of the gateway is nnn.nnn.nnn.nnn. Wherein, the first nnn
ranges from 1 to 223 (except 127) and the other three range from 0 to
255. You are recommended to ask your network administrator for an
available gateway.
NOTE: The RF signal generator always tries to acquire the IP address
configuration in the order of DHCP, auto IP and manual IP and the three
methods cannot be disabled at the same time.
DNS
Press DNS to set the IP address of the DNS server. The format of the DNS
address is nnn.nnn.nnn.nnn. Wherein, the first nnn ranges from 1 to 223
(except 127) and the other three range from 0 to 255. You are
recommended to ask your network administrator for an available address.
3. GPIB
Set the GPIB address.
Press GPIB and you can use the numeric keys, knob or direction keys to modify
the parameter. The range is from 0 to 30.