User`s guide

Chapter 2 Front Panel Operations RIGOL
DSG3000 Users Guide 2-15
F
T
Start
Frequency
Stop
Frequency
Start
Frequency
Stop
Frequency
Ramp
Triangle
Ramp: the sweep period always starts from the start frequency or start level
to the stop frequency or stop level and the sweep sequence is similar to a
ramp waveform.
Triangle: the sweep period always starts from the start frequency or start
level to the stop frequency or stop level and then returns back to the start
frequency or start level. The sweep sequence is similar to a triangle
waveform.
Sweep Mode
Press SWEEP Mode to select “Cont” or “Single” sweep and the default isCont”.
Cont: after selecting continuous sweep, the continuous sweep label is displayed
in the frequency or amplitude area in the user interface. When the trigger
condition is met, the instrument starts to sweep continuously according to the
current setting.
Single: after selecting single sweep, the single sweep label is displayed in the
frequency or amplitude area in the user interface. When the trigger condition is
met, the instrument performs one sweep according to the current setting and
then stops.