To Select the Pulse Mode
Press Pulse Source to select Intmodulation source; press Mode to select
Single, “Doubleor Train(option PUG-DSG3000).
Single: only one pulse signal is generated for a pulse period. This is the default
pulse mode.
Double: two pulse signals are generated for a pulse period. At this point, Delay
and #2 Width are available and you can set the delay and pulse width.
Train: a plurality of pulse signals are generated for a pulse period. At this point,
Period, Width, Delay and #2 Width are grayed out and disabled. You can
press Train List to edit the desired pulse train.
NOTE: When Extmodulation source is selected, this menu is grayed out and
disabled. When selecting Train or editing Train List, you need to install the option
PUG-DSG3000. For the specific installation steps, please refer to
DSG3000 Firmware
and Options Installation Instruction
.
To Set the Pulse Period
The pulse period is the time interval between two neighboring pulses in
periodically-repeating pulse sequence.
Press Pulse Source to select Intmodulation source; press Period to set the
period of the pulse modulating signal.
Use the numeric keyboard to input the desired value and select the desired unit
from the pop-up unit menu or unit keys. You can also press Enter to select the
default unit (s).
You can also use the knob to modify this parameter.
The range of pulse period is from 40 ns to 170 s.
The pulse period determines the repeating frequency of the internal pulse
modulating signal.
NOTE: When Extmodulation source or Train pulse mode is selected, this menu is
grayed out and disabled.
To Set the Pulse Width
The pulse width is the time that the pulse can hold at the maximum value.
Press Pulse Source to select Intmodulation source; press Mode to select
Singleor Double. At this point, you can set the corresponding pulse width and
delay.