User`s guide

RIGOL Chapter 2 Front Panel Operations
2-32 DSG3000 Users Guide
The pulse train edited as shown in the figure below, wherein the repeat number of
the first line is two.
On Time
Off Time
Dwell Time
Repeat 1
Repeat 2
NOTE: When editing pulse train list, you need to install the option PUG-DSG3000.
For the specific installation steps, please refer to
DSG3000 Firmware and Options
Installation Instruction
.
Run
Press Run, you can set the current pulse value to the internal modulating signal.
At this point, if Intmodulation source and Trainpulse mode are selected and
Pulse Outswitch is turned on, the instrument outputs the corresponding pulse
sequence from the [PULSE IN/OUT] connector at the rear panel.
Insert
Press Insert to insert a row with the same pulse value below the current row. At
this point, the number of rows of the pulse train list increases by one.
Delete
Press Delete to delete the pulse value of the row currently selected. At this
point, the number of rows of the pulse train list reduces by one.
Goto Row
Press Goto Row to select the desired row for edit in the pop-up menu. It is
usually used to modify the pulse value of the specified row.
N: press n and use the numeric keyboard to input the desired row number to
select that row. The row number input should not be greater than the total
number of rows of the current list.
Top: press Top to select the first row of the current list.
Mid: press Mid to select the row at the middle of the current list.
Bottom: press Bottom to select the last row of the current list.
When the desired row is selected, press
to return to the previous menu to
modify the calibration value of the row currently selected.