[:SOURce]:IQ:TRIGger:DURation:UNIT 
Syntax  [:SOURce]:IQ:TRIGger:DURation:UNIT SEQUENCE|SAMPLES 
[:SOURce]:IQ:TRIGger:DURation:UNIT? 
Description  Set the duration unit of the IQ wavetable in "Single" trigger.  
Query the duration unit of the IQ wavetable in "Single" trigger. 
Parameter 
Name  Type  Range  Default 
SEQUENCE|SAMPLES  Discrete  SEQUENCE|SAMPLES   SAMPLES 
Explanation    SEQUENCE: trigger by the waveform segment. 
  SAMPLES: trigger by the data point. 
Return Format 
The query returns the duration unit of the IQ wavetable in "Single" trigger. For 
example, SAMPLES. 
Example  :IQ:TRIG:DUR:UNIT SAMPLES 
:IQ:TRIG:DUR:UNIT? 
Related 
Command 
[:SOURce]:IQ:TRIGger:OPTMode 
[:SOURce]:IQ:TRIGger:INHibit 
Syntax  [:SOURce]:IQ:TRIGger:INHibit <value> 
[:SOURce]:IQ:TRIGger:INHibit? 
Description  Set the trigger inhibit of the IQ modulation baseband signal. 
Query the trigger inhibit of the IQ modulation baseband signal. 
Parameter 
Name 
Type 
Range 
Default 
<value> 
Integer 
0 to 65535 
0 
Explanation    Trigger inhibit refers to the time from when a trigger signal is received to when 
the instrument receives the next trigger signal.   
  This command is valid only when "Ext" trigger mode is selected. <value> 
describes the number of points (
i
N
). The actual time (
i
T
) can be obtained 
according to the current sample rate (
a
S
): 
aii
 SN T =
.  
  After the trigger inhibit is set, you can rotate the knob to modify the inhibit at 
the current step. At this point, you can set and query the current step using the 
[:SOURce]:IQ:TRIGger:INHibit:STEP command. 
Return Format 
The query returns the trigger inhibit. For example, 5000. 
Example  :IQ:TRIG:INH 5000 
:IQ:TRIG:INH? 
Related 
Commands 
[:SOURce]:IQ:TRIGger:INHibit:STEP 
[:SOURce]:IQ:TRIGger:MODe 