Instructions

RIGOL Chapter 2 Command System
2-14 DSG800 Programming Guide
[:SOURce]:AM:EXT:COUP
Syntax [:SOURce]:AM:EXT:COUP AC|DC
[:SOURce]:AM:EXT:COUP?
Description Set the coupling mode of AM external modulation.
Query the coupling mode of AM external modulation.
Parameter
Name
Type
Range
Default
AC|DC
Discrete
AC|DC
AC
Explanation AC: set the coupling mode of AM external modulation to "AC".
DC: set the coupling mode of AM external modulation to "DC".
When the modulation source of AM is set to "Int", this command is invalid.
Return Format
The query returns AC or DC.
Example :AM:EXT:COUP AC
:AM:EXT:COUP?
Related
Command
[:SOURce]:AM:SOURce
[:SOURce]:AM:EXT:IMP
Syntax [:SOURce]:AM:EXT:IMP 50|600|100k
[:SOURce]:AM:EXT:IMP?
Description Set the impedance of AM external modulation.
Query the impedance of AM external modulation.
Parameter
Name Type Range Default
50|600|100k Discrete 50|600|100k 100k
Explanation 50: set the impedance of AM external modulation to "50ohm".
600: set the impedance of AM external modulation to "600ohm".
100k: set the impedance of AM external modulation to "100kohm".
When the modulation source of AM is set to "Int", this command is invalid.
Return Format The query returns 50, 600 or 100k.
Example :AM:EXT:IMP 600
:AM:EXT:IMP?
Related
Command
[:SOURce]:AM:SOURce