[:SOURce]:FM Command Subsystem
Command List:
[:SOURce]:FM[:DEViation]
[:SOURce]:FM[:DEViation]:STEP[:INCRement]
[:SOURce]:FM:EXT:COUP
[:SOURce]:FM:EXT:IMP
[:SOURce]:FM:FREQuency
[:SOURce]:FM:FREQuency:STEP[:INCRement]
[:SOURce]:FM:SOURce
[:SOURce]:FM:STATe
[:SOURce]:FM:WAVEform
[:SOURce]:FM[:DEViation]
Syntax [:SOURce]:FM[:DEViation] <value>
[:SOURce]:FM[:DEViation]?
Description Set the FM frequency deviation.
Query the FM frequency deviation.
Parameter
Name
Type
Range
Default
<value> Real
100mHz to
1MHz
10kHz
Explanation When <value> is set in "Number" form, the default unit is Hz; for example,
20000. In addition, <value> can also be set in "Number + Unit" form; for
example, 20kHz.
After the frequency deviation is set, you can rotate the knob to modify the
deviation at the current step. You can set and query the current step using the
[:SOURce]:FM[:DEViation]:STEP[:INCRement] command.
Return Format
The query returns the FM frequency deviation. For example, 20.00000kHz.
Example :FM:DEV 20kHz
:FM:DEV?
Related
Command
[:SOURce]:FM[:DEViation]:STEP[:INCRement]