Instructions
RIGOL Chapter 2 Command System
2-38 DSG800 Programming Guide
[:SOURce]:IQ:TRIGger:OPTMode
Syntax [:SOURce]:IQ:TRIGger:OPTMode RETRig|AMDAuto|AMDRetrig|SINGle
[:SOURce]:IQ:TRIGger:OPTMode?
Description Set the operation mode after the IQ modulation baseband signal is triggered.
Query the operation mode after the IQ modulation baseband signal is triggered.
Parameter
Name
Type
Range
Default
RETRig|AMDAuto|
AMDRetrig|SINGle
Discrete
RETRig|AMDAuto|
AMDRetrig|SINGle
RETRig
Explanation RETRig: select the "Retrig" mode. At this point, the instrument outputs the
baseband signal continuously and restarts to output the signal each time a
trigger is received.
AMDAuto: select the "Arm Auto" mode. The instrument starts outputting the
waveform continuously each time a trigger is received until "Arm ARB" is
selected and then waits for the next trigger.
AMDRetrig: select the "Arm Retrig" mode. The instrument starts outputting the
waveform continuously each time a trigger is received; the instrument restarts
outputting the signal when another trigger is received until "Arm ARB" is
selected and then waits for the next trigger.
SINGle: select the "Single" mode. The instrument outputs the specified length
(specified in "Duration") of waveform each time a trigger is received and then
stops to wait for the next trigger.
Return Format The query returns the operation mode after the IQ modulation baseband signal is
triggered. For example, RETRIG.
Example :IQ:TRIG:OPTM RETR
:IQ:TRIG:OPTM?
Related
Commands
[:SOURce]:IQ:TRIGger:ARB
[:SOURce]:IQ:TRIGger:DURation
[:SOURce]:IQ:TRIGger:SEGMent:CURRent?
Syntax [:SOURce]:IQ:TRIGger:SEGMent:CURRent?
Description Query the number of the current wavetable segment.
Return Format The query returns the number of the current wavetable segment. For example, 1.
[:SOURce]:IQ:TRIGger:SEGMent:EXECute
Syntax [:SOURce]:IQ:TRIGger:SEGMent:EXECute
Description Execute the trigger of the next segment.
Explanation
This command is only valid when a "Segment" file is loaded and the segment trigger
mode is set to "Next Seg" or "Seamless".
Related
Command
[:SOURce]:IQ:TRIGger:SEGMent:MODE