Instructions
RIGOL Chapter 2 Command System
2-46 DSG800 Programming Guide
[:SOURce]:PM Command Subsystem
Command List:
[:SOURce]:PM[:DEViation]
[:SOURce]:PM[:DEViation]:STEP[:INCRement]
[:SOURce]:PM:EXT:COUP
[:SOURce]:PM:EXT:IMP
[:SOURce]:PM:FREQuency
[:SOURce]:PM:FREQuency:STEP[:INCRement]
[:SOURce]:PM:SOURce
[:SOURce]:PM:STATe
[:SOURce]:PM:WAVEform
[:SOURce]:PM[:DEViation]
Syntax [:SOURce]:PM[:DEViation] <value>
[:SOURce]:PM[:DEViation]?
Description Set the phase deviation of ØM.
Query the phase deviation of ØM.
Parameter
Name
Type
Range
Default
<value>
Real
0rad to 5rad
5rad
Explanation When <value> is set in "Number" form, the default unit is rad. Besides,
<value> can also be set in "Number + Unit" form; for example, 2rad.
The default unit of the return value is rad.
After the phase deviation is set, you can rotate the knob to modify the phase
deviation at the current step. At this point, you can query and set the current
step using the [:SOURce]:PM[:DEViation]:STEP[:INCRement] command.
Return Format The query returns the phase deviation of ØM. For example, 2.000000.
Example
:PM:DEV 2
:PM:DEV?
Related
Command
[:SOURce]:PM[:DEViation]:STEP[:INCRement]