Press MATH Operate to select “Logic”:
Press Formula to select the desired logic formula and the default is AND.
Press Source A and Source B respectively to select the desired channels (CH1,
CH2 or any channel of D0-D15).
Press and use to adjust the vertical position of the operation results.
Press
and use to adjust the vertical scale of the operation results.
Press Invert to turn the inverted display of the operation results on or off.
Press Threshold A and use to set the threshold of source A in logic
operation.
Press Threshold B and use to set the threshold of source B in logic
operation.
Note: When Source A or Source B is set to any channel of D0-D15,
Threshold A or Threshold B will be hidden automatically and cannot be set.
Press Label to define a label for the operation results. For the details, please
refer to
MATH Label.