User Manual

RIGOL 11 Waveform Record
MSO4000/DS4000 Users Guide
11-10
setting, refer to the introductions in Analysis Based on Traceand
Analysis Based on Pass/Fail Mask.
Analysis Based on Trace
Press Analyze and select “Trace”. Then, set the template used in analysis based on
trace through the method below.
1. Trace
Press Trace to select the creation method of analysis template.
Current Frame: select the current frame as the analysis template.
Average: select the average of the current data frame as the analysis
template.
2. Setup Template
Press SetupTemplate to configure the template immediately. After the
analysis starts, the oscilloscope compares each frame with the template to
compute the difference value and determines whether error frame exists by
comparing the difference value with the threshold currently set.
3. TemplateDisp
Press TemplateDisp to enable or disable template display.