Data Sheet

RIGOL 5 To Trigger the Oscilloscope
MSO4000/DS4000 Users Guide
5-32
Tx: transmission signal on the CAN signal line.
CAN_H: actual CAN_H bus signal.
CAN_L: actual CAN_L bus signal.
Differential: CAN differential bus signal connected to the analog channel via
the differential probe.
Trigger Condition:
Press When to select the desired trigger condition.
SOF: trigger on the start frame of the data frame.
EOF: trigger on the end frame of the data frame.
Frame Type: after this type is selected, press Frame Type to select to trigger
on Data”, “Remote”, “Error” or “OverLoad” frame. Set the following parameters
when “Data” or “Remote” is selected.
Data” trigger:
--press ID Setup and select “Specific ID” or “Random ID”. When “Specific ID” is
selected, press ID Format to select “Standard” or “Expand”; press ID Data
and use
to input the desired value. The range is from 0 to 2047 (standard ID
format) or 0 to 536870911 (expanded ID format).
--press Byte Length and use to input the desired value. The range is from
1 to 8.
--press CurrentBit to select the desired data bit and the range is from 0 to
(“Byte Length”×8-1).
--press Data to set the data pattern of the current bit to X, H or L.
--press AllBits to set the data pattern of all the data bits to the data pattern
specified in Data.
“Remote” trigger:
--press ID Setup and select “Specific ID” or “Random ID”. When “Specific ID” is
selected, press ID Format and select “Standard” or “Expand”. Press ID Data
and use
to input the desired value. The range is from 0 to 2047 (standard ID
format) or 0 to 536870911 (expanded ID format).
Frame Error: after selecting this type, press Error Type to select to trigger on
the “Bit Fill”, “Answer Error”, “Check Error”, “Format Error” or “Random Error.
Baud:
Press Baud to set the CAN baud to match the CAN bus signal and the values
available are 10 kb/s (default), 20 kb/s, 33.3 kb/s, 50 kb/s, 62.5 kb/s, 83.3 kb/s, 100