Data Sheet

RIGOL 8 Protocol Decoding
MSO4000/DS4000 Users Guide
8-14
3. MISO Setting
Press MISO to enter the MISO data line setting interface.
Press Channel to select any channel (CH1-CH4 or D0-D15) as the MISO
data channel. When Noneis selected, this data line is not set.
Press Polarity to set the polarity of the MISO data line to (the high
level is 1) or
(the low level is 1).
Press Threshold to set the threshold of the MISO data channel.
4. MOSI Setting
Press MOSI to enter the MOSI data line setting interface.
Press Channel to select any channel (CH1-CH4 or D0-D15) as the MOSI
data channel. When OFFis selected, this data line is not set.
Press Polarity to set the polarity of the MOSI data line (the high level
is 1) or
(the low level is 1).
Press Threshold to set the threshold of the MOSI data channel.
5. Data Bits Setting
Press Data Bits to set the number of bits of each frame of data. The range
available is from 4 to 32.
6. Endian Setting
Press Endian to select LSBor MSBand the default is “MSB”.
7. Display-related Setting
Press Format to set the display format of the bus to Hex, Decimal, Binary or
ASCII.
Press Offset and use to adjust the vertical display position of the bus.
Press BusStatus to turn the bus display on or off.
8. Decoding Table
The decoding table displays the decoded data, the corresponding line number,
time and error information on the MOSI or MISO data line in table format. This
can be useful when observing longer data transimissions by presenting the data
in a tabular format.
Press Event Table Event Table to select ON(note that this operation is
only available when BusStatus is set to ON) to enter the decoding table