Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

Chapter 5 To Trigger the Oscilloscope RIGOL
MSO5000-E User Guide 5-49
Trigger Parameter Setting:
Set the trigger parameter (noise rejection) under this trigger type. For details, refer
to descriptions in "Noise Rejection".
Trigger LEVEL/Threshold Level:
Rotate the Trigger
LEVEL knob to adjust the trigger level/threshold level. Refer
to "
Trigger LEVEL/Threshold Level". The current trigger level/threshold level
value is displayed at the upper-right corner of the screen.
MIL-STD-1553 Trigger (Option)
1553B is the abbreviation for the MIL-STD-1553 bus. MSO5000-E can trigger on the
sync field of 1553B bus, and can also trigger on the specified data word, command
word, status word, or error type.
The formats of the command word, data word, and status word of the 1553B bus is
shown in the following figure.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Bit
Times
Bit
Times
Data
Word
Bit
Times
Status
Word
Sync
Remote Terminal
Address
5
5 5
T/R
Subaddress/Mode
Word Count/
Mode Code
P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
16
Sync
16-bit Data
Sync
Remote Terminal
Address
M
e
s
s
a
g
e
E
r
r
o
r
I
n
s
t
r
u
m
e
n
t
a
t
i
o
n
R
e
s
e
r
v
e
d
S
e
r
v
i
c
e
R
e
q
u
e
s
t
B
r
o
a
d
c
a
s
t
C
M
D
R
e
c
e
i
v
e
d
B
u
s
y
S
u
b
s
y
s
t
e
m
F
l
a
g
D
y
n
a
m
i
c
B
u
s
A
c
c
e
p
t
a
n
c
e
T
e
r
m
i
n
a
l
F
l
a
g
O
d
d
P
a
r
i
t
y
5 3
Command
Word
Figure 5-23 Formats of the Command Word, Data Word, and Status Word of the
1553B Bus