Instructions
Table Of Contents
- Guaranty and Declaration
- Safety Requirement
- MSO5000-E Series Overview
- Document Overview
- Quick Start
- General Inspection
- Appearance and Dimensions
- To Prepare for Use
- Front Panel Overview
- Rear Panel Overview
- Front Panel Function Overview
- User Interface
- Touch Screen Controls
- Parameter Setting Method
- To Use the Kensington Security Lock
- To Use the Built-in Help System
- To View the Option Information and the Option Installation
- To Set the Vertical System
- To Set the Horizontal System
- To Set the Sample System
- To Trigger the Oscilloscope
- Trigger Source
- Trigger LEVEL/Threshold Level
- Trigger Mode
- Trigger Coupling
- Trigger Holdoff
- Noise Rejection
- Trigger Type
- Edge Trigger
- Pulse Trigger
- Slope Trigger
- Video Trigger
- Pattern Trigger
- Duration Trigger
- Timeout Trigger
- Runt Trigger
- Window Trigger
- Delay Trigger
- Setup/Hold Trigger
- Nth Edge Trigger
- RS232 Trigger (Option)
- I2C Trigger (Option)
- SPI Trigger (Option)
- CAN Trigger (Option)
- FlexRay Trigger (Option)
- LIN Trigger (Option)
- I2S Trigger (Option)
- MIL-STD-1553 Trigger (Option)
- Zone Trigger
- Trigger Output Connector
- Operations and Measurements
- Digital Voltmeter (DVM) and Frequency Counter
- Power Analysis (Option)
- Histogram Analysis
- Digital Channel
- Protocol Decoding
- Reference Waveform
- To Enable Ref Function
- To Select the Reference Channel
- To Select the Ref Source
- To Adjust the Ref Waveform Display
- To Save to Internal Memory
- To Clear the Display of the Reference Waveform
- To View Details of the Reference Waveform
- To Reset the Reference Waveform
- Color Setting
- Label Setting
- To Export to Internal or External Memory
- To Import from Internal or External Memory
- Pass/Fail Test
- Waveform Recording & Playing
- Search and Navigation Function
- Display Control
- Function/Arbitrary Waveform Generator (Option)
- Store and Load
- System Utility Function Setting
- Remote Control
- Troubleshooting
- Appendix
- Index

Chapter 10 Digital Channel RIGOL
MSO5000-E User Guide 10-1
Chapter 10 Digital Channel
MSO5000-E series oscilloscope has a standard configuration of the logic analyzer (LA)
function, and it has 16 digital channels. The default channel label is D15-D0. The
oscilloscope compares the voltages acquired in each sample with the preset logic
threshold. If the voltage of the sample point is greater than the threshold, it will be
stored as logic 1; otherwise, it will be stored as logic 0. The oscilloscope displays
logic levels ("1" and "0") in the form of a graph for you to easily detect and analyze
the errors in circuit design (hardware design and software design).
Before using the digital channels, connect the oscilloscope and the device under test
using PLA2216 active logic probe option. To apply to different application scenarios,
PLA2216 provides two connection methods to connect the signal under test. For
details, refer to
PLA2216 Active Logic Probe User Guide
.
Note: The digital channel input terminal does not support hot plug. Please do not
insert or pull out the logic probe when the instrument is powered on.
Contents in this chapter:
To Select the Digital Channel
To Enable/Disable the Digital Channel
To Set the Threshold and Calibrate Probe
Auto Arrangement Setting
To Set the Waveform Display Size
To Set the Label
Group Setting
Waveform Color of the Digital Channel