Instructions

RIGOL Chapter 2 Command System
2-92 MSO7000/DS7000 Programming Guide
:MASK:X
Syntax
:MASK:X <x>
:MASK:X?
Description
Sets or queries the horizontal adjustment parameter of the pass/fail test mask. The
default unit is div.
Parameter
Name
Type
Range
Default
<x>
Real
0.01 div to 2 div
0.24 div
Return
Format
The query returns the current horizontal adjustment parameter in scientific notation.
Example
:MASK:X 0.28 /*Sets the horizontal adjustment parameter to 0.28 div.*/
:MASK:X? /*The query returns 2.800000E-1.*/
:MASK:Y
Syntax
:MASK:Y <y>
:MASK:Y?
Description
Sets or queries the vertical adjustment parameter of the pass/fail test mask. The default
unit is div.
Parameter
Name
Type
Range
Default
<y>
Real
0.04 div to 2 div
0.48 div
Return
Format
The query returns the current vertical adjustment parameter in scientific notation.
Example
:MASK:Y 0.36 /*Sets the vertical adjustment parameter to 0.36 div.*/
:MASK:Y? /*The query returns 3.600000E-1.*/
:MASK:CREate
Syntax
:MASK:CREate
Description
Creates the pass/fail test mask with the currently set horizontal and vertical adjustment
parameters.
Description
This command is only valid when the pass/fail test function is enabled and not in running
state.
:MASK:RESet
Syntax
:MASK:RESet
Description
Resets the number of frames that passed and failed the pass/fail test, as well as the total
number of frames.