RIGOL English Quick Guide 中文 MSO7000/DS7000 Series Digital Oscilloscope Mar. 2018 RIGOL TECHNOLOGIES, INC.
RIGOL Guaranty and Declaration English Copyright © 2018 RIGOL TECHNOLOGIES, INC. All Rights Reserved. Trademark Information RIGOL is a registered trademark of RIGOL TECHNOLOGIES, INC. Publication Number QGA22102-1110 Notices RIGOL products are covered by P.R.C. and foreign patents, issued and pending. RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at the company’s sole decision.
RIGOL English General Safety Summary 1. 2. 3. 4. 5. 6. Only the exclusive power cord designed for the instrument and authorized for use within the local country could be used. Ensure that the instrument is safely grounded. Observe all terminal ratings. Use proper overvoltage protection. Do not operate without covers. Do not insert objects into the air outlet. 7. 8. 9. 10. 11. 12. 13. 14. 15. Use the proper fuse. Avoid circuit or wire exposure. Do not operate the instrument with suspected failures.
RIGOL Safety Symbols on the Product: Hazardous Voltage Safety Warning Protective Earth Terminal English Chassis Ground Test Ground Care and Cleaning Care Do not store or leave the instrument where it may be exposed to direct sunlight for long periods of time. Cleaning Clean the instrument regularly according to its operating conditions. 1. Disconnect the instrument from all power sources. 2. Clean the external surfaces of the instrument with a soft cloth dampened with mild detergent or water.
RIGOL English Format Conventions in this Manual 1. Key The key on the front panel is denoted by the format of "Key Name (Bold) + Text Box" in the manual. For example, Utility denotes the "Utility" key. 2. Menu The menu items are denoted by the format of "Menu Word (Bold) + Character Shading". For example, System denotes the "System" menu item under Utility. 3. Operation Procedures denotes the next step of operation.
RIGOL General Inspection English 1. Inspect the packaging If the packaging has been damaged, do not dispose the damaged packaging or cushioning materials until the shipment has been checked for completeness and has passed both electrical and mechanical tests. The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument.
RIGOL English 1 2 34 5 6 7 8 Digital Oscilloscope 500MHz 10GSa/s 9 10 11 12 13 CLEAR Menu Off STOP RUN AUTO Touch Lock SINGLE Intensity Storage Display Utility Quick Acquire Menu Measure Cursor Navigate Menu LA Ref Decode Mode Trigger Math Force Search Zoom e Wav Horizontal Vertical OFFSET OFFSET Zero 1 GⅠ Zero 2 GⅡ 50% OFFSET Zero 3 Default 4 Back For output only GⅠ 20 19 GⅡ 18 17 16 15 14 Figure 1 Front Panel Table 1 Front Panel Description No.
RIGOL 1 10 2 9 8 3 4 7 English 5 6 Figure 2 Rear Panel Table 2 Rear Panel Description No.
RIGOL English 1 24 23 2 22 3 4 21 5 6 7 20 19 8 9 18 17 10 11 12 16 15 14 13 Figure 3 User Interface Table 3 User Interface Icons No. Description No.
RIGOL To Prepare for Use English To Adjust the Supporting Legs Adjust the supporting legs properly to use them as stands to tilt the oscilloscope upwards for stable placement of the oscilloscope as well as better operation and observation, as shown in Figure 4. Supporting Legs (a) To unfold the supporting legs (b) To fold the supporting legs Figure 4 To Adjust the Supporting Legs To Connect to AC Power The input AC power requirements of the oscilloscope are 100~240 V, 45~440 Hz.
RIGOL English Turn-on Checkout When the oscilloscope is connected to power, press the Power key at the lower-left corner of the front panel to start the oscilloscope. (You can also press Utility System Power status, and select "Switch On". After the instrument is connected to power source, it will start directly. You can also enable the touch screen to perform the above menu operation.) During the start-up process, the oscilloscope performs a series of self-tests.
RIGOL English Figure 6 To Connect the Passive Probe After you connect the passive probe, check the probe function and probe compensation adjustment before making measurements. For detailed procedures, refer to "Function Inspection" in this manual and the "Probe Compensation" section introduced in MSO7000/DS7000 User's Guide. Connect the active probe: Take RP7080 (use the active differential probe head) as an example. 1. Connect the probe head to the preamp of the active probe, as shown in Figure 7.
RIGOL English Figure 8 To Connect the Active Probe 3. Use the probe auxiliary equipment to connect the probe front to the circuit under test. For details about the probes, refer to RP7000 Series Active Probe User's Guide. After connecting the active probe, you can perform probe calibration and offset voltage adjustment if necessary. For detailed procedures, refer to the descriptions of the active probe in user's guide. Connect the logic probe: 1.
RIGOL Note: English Before you connect the logic probe to the signal under test, connect logic probe's adapter provided in the accessories to its corresponding channel group. The digital channel input terminal does not support hot plugging. Please do not insert or pull out the logic probe when the instrument is in power-on state. Function Inspection 1. 2. 3. Press Default on the front panel, and then a prompt message "Restore default?" is displayed.
RIGOL English Figure 11 Square Waveform Signal 6. Use the same method to test the other channels. If the square waveforms actually shown do not match that in the figure above, please perform "Probe Compensation" introduced in MSO7000/DS7000 User's Guide. WARNING To avoid electric shock when using the probe, please make sure that the insulated wire of the probe is in good condition. Do not touch the metallic part of the probe when the probe is connected to high voltage source.
RIGOL Tap the virtual keypad to set the label name and the filename. English Tap close button at the upper-right corner of the message box to close it. Tap and operate the windows on the screen. Figure 12 Tap Gesture Pinch&Stretch Pinch or stretch two points on the screen with two fingers to zoom in or out the waveform.
RIGOL English Figure 14 Drag Gesture Rectangle Drawing Enable the function navigation, and then tap the "Draw rect" icon to switch to the rectangle drawing mode. Drag to draw a rectangle on the screen, as shown in Figure 15. The actions supported by the rectangle drawing include: Select "Trigger zone A": Draw the region for Trigger zone A; Open Trigger zone A; Open the "Zone trig" menu.
RIGOL To Use the Built-in Help System English The help system of this oscilloscope provides instructions for all the function keys on the front panel and their corresponding menu keys. The steps for opening the built-in help system are as follows: at 1. Using the touch screen function, tap the function navigation icon the lower-left corner of the touch screen to enable the function navigation. 2. Tap the "Help" icon, and then the "Help" menu is displayed on the screen. 3.
RIGOL English give you different help information. Method 2: In the "Help Options", rotate the multifunction knob to switch among the help options to get the corresponding help information. Method 3: Enable the touch screen and tap the desired help option to get the corresponding help information. Tip Help information for other keys and buttons: Power key : powers on/off the instrument. Menu Off key: displays or hides menus. By default, menus are displayed.
RIGOL Parameter Setting Method English For the MSO7000/DS7000 series, you can use the multifunction knob or enable the touch screen to set the parameters of MSO7000/DS7000 series. The common parameter setting methods are as follows: Method 1: , rotate the multifunction knob on the For the parameters with the sign front panel directly to select the parameter item or modify the parameter value.
RIGOL English values, you can also press OK directly to close the numeric keypad. At this time, the unit of the parameter is the default unit. In the numeric keypad, you can also perform the following operations: Delete the parameter value that has been input. Set the parameter to a maximum or minimum value (sometimes, the maximum or minimum value are the specified one for the current state). Set the parameter to a default value. Clear the parameter input field.
RIGOL Fuse Replacement English If you need to replace the fuse, use only the specified fuse (AC 250 V, T3.15 A; 5.2 mm×20 mm) and perform the following operations, as shown in Figure 18: 1.Turn off the instrument, cut off the power, and remove the power cord. 2.Use a small straight slotted screwdriver to pry out the fuse holder. 3.Take out the fuse. 4.Replace the old fuse with a specified fuse. 5.Install the fuse holder.
RIGOL English Remote Control MSO7000/DS7000 series digital oscilloscope can be connected to the PC via the USB, LAN, or GPIB interface to set up communication and realize remote control through the PC. The remote control can be realized by using SCPI (Standard Commands for Programmable Instruments) commands. MSO7000/DS7000 series digital oscilloscope supports two ways of remote control: user-defined programming and PC software (e.g. RIGOL Ultra Sigma). More Product Information 1.
RIGOL 快速指南 中文 MSO7000/DS7000 系列数字示波器 2018 年 3 月 RIGOL TECHNOLOGIES, INC.
RIGOL 保证和声明 版权 © 2018 苏州普源精电科技有限公司 中文 商标信息 RIGOL 是苏州普源精电科技有限公司的注册商标。 文档编号 QGA22002-1110 声明 本公司产品受中国及其他国家和地区的专利(包括已取得的和正在申请的 专利)保护。 本公司保留改变规格及价格的权利。 本手册提供的信息取代以往出版的所有资料。 本手册提供的信息如有变更,恕不另行通知。 对于本手册可能包含的错误,或因手册所提供的信息及演绎的功能以及因 使用本手册而导致的任何偶然或继发的损失,RIGOL 概不负责。 未经 RIGOL 事先书面许可,不得影印、复制或改编本手册的任何部分。 产品认证 RIGOL 认证本产品符合中国国家产品标准和行业产品标准及 ISO9001:2008 标 准和 ISO14001:2004 标准,并进一步认证本产品符合其他国际标准组织成员的 相关标准。 联系我们 如您在使用此产品或本手册的过程中有任何问题或需求,可与 RIGOL 联系: 电子邮箱:service@rigol.com 网址:www.rigol.
RIGOL 一般安全概要 1. 中文 2. 3. 4. 5. 6. 7. 8. 请使用所在国家认可的本产品 专用电源线。 请确保产品可靠接地。 查看所有终端额定值。 请使用合适的过压保护。 请勿开盖操作。 请勿将异物插入排风口。 请使用合适的保险丝。 避免电路外露。 9. 10. 11. 12. 13. 14. 15.
RIGOL 保养与清洁 保养 请勿将仪器放置在长时间受到日照的地方。 清洁 中文 请根据使用情况定期对仪器进行清洁。方法如下: 1. 断开电源。 2. 用柔和的清洁剂或清水浸湿软布擦拭仪器外部。清洁带有液晶显示屏的仪 器时,请注意不要划伤液晶显示屏。 注意 请勿使任何腐蚀性的液体沾到仪器上,以免损坏仪器。 警告 重新通电之前,请确认仪器已经干透,避免因水分造成电气短路甚 至人身伤害。 文档概述 本文档用于指导用户快速了解MSO7000/DS7000系列数字示波器的前后面板、用 户界面及基本操作方法等。 提示 本手册的最新版本可登陆 RIGOL 网址(www.rigol.com)进行下载。 文档格式的约定 1. 按键 用“按键字符(加粗)+文本框”表示前面板按键,如 Utility 表示“Utility” 按键。 2.
RIGOL 3. 4.
RIGOL 一般性检查 1. 检查运输包装 如运输包装已损坏,请保留被损坏的包装或防震材料,直到货物经过完全 检查且仪器通过电性和机械测试。 中文 因运输造成仪器损坏,由发货方和承运方联系赔偿事宜。RIGOL公司恕不 进行免费维修或更换。 2. 检查整机 若存在机械损坏或缺失,或者仪器未通过电性和机械测试,请联系您的 RIGOL 经销商。 3. 检查随机附件 请根据装箱单检查随机附件,如有损坏或缺失,请联系您的RIGOL经销商。 产品简介 MSO7000/DS7000 系列数字示波器是基于 RIGOL 独创的 Ultra Vision II 代技术 的多功能、高性能数字示波器,集 6 种仪器于一身,包括示波器、16 通道逻辑 分析仪、双通道函数/任意波形发生器、数字电压表、6 位频率计和累加器、协 议分析仪,具有超高的采样带宽比和存储深度、良好的显示效果、优异的波形捕 获率和强大的数据分析功能,多项指标均达业界一流水平,同时还提供从主机、 选附件到应用软件的完备解决方案,对工控、电源、汽车电子等工业行业客户具 有突出的吸引力。 前面板、后面板和主界面(显示屏)的简要介绍请分别参考图 1(具体说明见表 1
RIGOL 1 2 34 5 6 7 8 Digital Oscilloscope 500MHz 10GSa/s 9 10 11 12 13 CLEAR Menu Off STOP RUN Math LA Ref Decode SINGLE Storage Display Utility Quick Acquire Menu Measure 中文 AUTO Touch Lock Intensity Cursor Navigate Menu Mode Trigger Force Search Zoom e Wav Horizontal Vertical OFFSET OFFSET Zero 1 GⅠ 2 GⅡ 50% OFFSET Zero Zero 3 Default 4 Back For output only GⅠ 20 19 GⅡ 18 17 16 15 14 图 1 前面板 表 1 前面板说明 编号 说明 1 电容触摸屏 2 功能菜单操作键 3 Quick 快捷键 4 多功能旋钮 5 常用
RIGOL 1 2 3 4 5 中文 10 9 8 7 6 图 2 后面板 表 2 后面板说明 编号 1 2 3 4 5 6 7 8 9 10 MSO7000/DS7000 快速指南 说明 手柄 LAN 接口 USB DEVICE 接口 USB HOST 接口 HDMI 高清视频输出 EXT 触发输入端 触发输出接口 锁孔 保险丝 AC 电源插孔 7
RIGOL 1 2 3 4 5 6 7 8 9 10 11 12 中文 24 23 22 21 20 19 18 17 16 15 14 13 图 3 用户界面 表 3 用户界面标识 编号 说明 1 模拟通道标签和波形 2 运行状态 3 水平时基 4 采样率和存储深度 5 自动测量标签 6 波形存储器 7 触发位置 8 运行/停止控制标识 9 水平位移 10 触发类型 11 触发源 12 触发电平/阈值电平 8 编号 13 14 15 16 17 18 19 20 21 22 23 24 说明 操作菜单 通知区域 任意波发生器 2 波形标签 任意波发生器 1 波形标签 数字通道状态区 CH4 状态标签 消息框 CH3 状态标签 CH2 状态标签 CH1 状态标签 数字通道标签和波形 功能导航 MSO7000/DS7000 快速指南
RIGOL 使用前准备 调节支撑脚 适当的调整支撑脚,将其作为支架使示波器向上倾斜,以稳定放置示波器,便于 中文 更好的操作和观察显示屏,如图 4 所示。 支撑脚 (a)打开支撑脚 (b)关闭支撑脚 图 4 调节支撑脚 连接电源 本示波器可输入交流电源的规格为:100~240 V,45~440 Hz。请使用附件提供 的电源线按图 5 所示将示波器连接到电源中。 电源插孔 MSO7000/DS7000 快速指南 图 5 连接电源 9
RIGOL 开机检查 中文 当示波器处于通电状态时,按前面板左下角的电源键 即可启动示波器。 (您 也可以通过按 Utility 系统 电源状态,选择“开关常开” ,示波器通电后 直接开机。上述菜单操作,您也可以通过触摸屏功能实现)。开机过程中示波器 执行一系列自检,自检结束后出现开机画面。 设置系统语言 MSO7000/DS7000 系列示波器支持多种系统语言, 您可以按 Utility 语言 设 置系统语言。您也可以参考本手册中的“使用内置帮助系统”内容打开“帮助” 功能菜单,然后按 语言 键设置系统语言。上述菜单操作,您也可以通过触摸屏 功能实现。 连接探头 RIGOL 为 MSO7000/DS7000 系列提供无源探头、有源探头和逻辑探头。探头 的具体型号请参考《MSO7000/DS7000 系列数据手册》 。有关探头的详细技术信 息请参考相应的探头用户手册。 连接无源探头: 1. 将探头的 BNC 端连接至示波器前面板的模拟通道输入端,如图 6 所示。 2.
RIGOL 请参考本手册中“功能检查”和本产品用户手册中“探头补偿”一节介绍的内容。 连接有源探头: 以 RP7080(使用差分有源探头前端)为例: 1. 将探头前端与有源探头放大器连接,如图 7 所示。 中文 图 7 连接探头前端与有源探头放大器 2. 将有源探头放大器的另一端连接至示波器前面板的模拟通道输入端,如图 8 所示。注意将探头推到紧闭的位置。 图 8 连接有源探头 3. 使用探头辅助装置将探头前端连接到待测电路中。探头详细信息请参考 《RP7000 系列有源探头用户手册》 。 连接有源探头后,您可以根据需要进行探头校准和偏移电压调整等,具体步骤请 参考本产品用户手册中关于有源探头内容的介绍。 连接逻辑探头: 1. 将逻辑探头单线端按正确的方向连接至示波器前面板的数字通道输入端,如 图 9 所示。 2.
RIGOL 逻辑探头,为适应不同的应用场合,RPL2316 提供了三种连接被测信号的方 法,具体请参考《RPL2316 逻辑探头用户手册》 。 中文 图 9 连接逻辑探头 注意: 将逻辑探头连接至待测信号前,须将附件提供的逻辑探头适配器与其对应 的通道组连接。 数字通道输入接口不支持热插拔,请勿在仪器带电的情况下插入或拔出逻 辑探头。 功能检查 1. 2. 3. 按示波器前面板 Default 键,屏幕弹出“确定恢复默认设置?”提示框, 按 确定 键或用触摸手势点击“确定”选项将示波器恢复为出厂默认配置。 将探头的接地鳄鱼夹连接至图 10 所示的“接地端” 。 使用探头连接示波器的通道 1(CH1)输入端和图 10 所示的“补偿信号输 出端” 。 补偿信号输出端 接地端 图 10 使用补偿信号 4. 5.
RIGOL 中文 图 11 方波信号 6. 用同样方法检查其他通道。如实际显示的方波形状与上图不相符,请执行 本产品用户手册中“探头补偿”一节介绍的内容。 警告 为避免使用探头时被电击,请首先确保探头的绝缘导线完好,并 且在连接高压源时不要接触探头的金属部分。 触摸屏操作 MSO7000/DS7000 系列提供 10.
RIGOL 中文 图 12 触摸手势 捏合 将两根手指靠拢在一起或分开。捏合手势可放大或缩小相关波形。需放大时,先 将两根手指先靠拢在一起,然后滑动分开;需缩小时,先将两根手指分开,然后 滑动在一起,如图 13 所示。捏合可实现的功能包括: 水平方向捏合可调整波形的水平时基。 垂直方向捏合可调整波形的垂直档位。 图 13 捏合手势 拖动 用单指按住拖动目标不放,然后将其拖至目标位置,如图 14 所示。拖动可实现 的功能包括: 拖动波形以改变波形位移或偏移。 拖动窗口控件以改变窗口位置(如数字键盘) 。 拖动光标以改变光标位置。 14 MSO7000/DS7000 快速指南
RIGOL 中文 图 14 拖动手势 矩形绘制 打开功能导航,然后点击“矩形绘制”图标,切换为矩形绘制模式,在屏幕上拖 动手指以绘制矩形,如图 15 所示。矩形绘制可实现的功能包括: 选择“区域触发 A” : 绘制区域触发 A 的区域; 打开区域触发 A; 打开“区域触发”菜单。 选择“区域触发 B” : 绘制区域触发 B 的区域; 打开区域触发 B; 打开“区域触发”菜单。 选择“直方图” : 绘制直方图的范围; 打开“直方图”菜单。 选择“水平缩放” :水平方向扩展波形。 选择“垂直缩放” :垂直方向扩展波形。 选择“波形缩放” :水平方向和垂直方向同时扩展波形。 图 15 矩形绘制手势 MSO7000/DS7000 快速指南 15
RIGOL 使用内置帮助系统 本示波器的帮助系统提供了前面板各功能按键及相应菜单键的说明。打开帮助系 统的步骤如下: 1. 中文 2. 3.
RIGOL 方法三: 使用触摸屏功能,通过触摸手势直接点击所需的帮助选项获取帮助信息。 提示 其他按键和旋钮帮助信息: 电源键 :电源开/关键。 Menu Off 键:菜单隐藏键,按此键可隐藏菜单。 Back 键:菜单返回键,按此键可返回上一级菜单或返回前一次 设置的功能菜单。 多功能旋钮 :非菜单操作时,转动该旋钮可调整波形显示的亮 度。菜单操作时,该旋钮背光灯变亮,对于含有多个参数选项的 菜单项,按下相应的菜单软键后,旋转该旋钮选择参数项然后再 按下该旋钮选中(有时旋转该旋钮即可选中指定的参数项) 。该旋 钮还可以用于修改参数、输入文件名等。 若菜单项置灰,您无法直接按前面板相应的菜单键获取相应的帮助信 息,您只能通过上述介绍的方法二或方法三获取帮助信息。 中文 参数设置方法 MSO7000/DS7000 系列的参数设置主要支持多功能旋钮和触摸屏两种输入方 式,常用的参数设置方法如下: 方法一: 对于菜单上显示 的参数,直接旋转前面板上的多功能旋钮 数项或修改参数值。 方法二: 对于菜单上显示 的参数,旋转前面板上的多功能旋钮 下即可选中参数项或修改参数值。 即可选择参
RIGOL 参数输入框 删除键 最大值键 最小值键 中文 默认值键 清零键 图 17 数字键盘 在数字键盘中,您可以旋转多功能旋钮 进行选择然后再按下该旋钮选中即可 输入该数值或单位,或者使用触摸屏功能,通过触摸手势点击数字键盘中的数值 或单位进行输入。输入全部数值并选择所需的单位后,数字键盘自动关闭,则完 成参数设置。另外,完成数值输入后,您也可以直接点击数字键盘中的“OK” 键关闭数字键盘,此时参数的单位为默认单位。在数字键盘中,您还可以进行以 下操作: 删除已输入参数数值。 将参数设置为最大值或最小值(有时特指当前状态下的最大值或最小值) 。 将参数设置为默认值。 清空参数输入框。 方法四: 对于菜单上无图标显示的参数,直接按相应的菜单软键即可切换设置所需的参数 (此方法适用于只有两个可选选项的参数) 。 提示 上述方法是示波器常用的参数设置方法,若某些参数有其他设置方法,将 在本产品用户手册的相关章节中详细介绍。 18 MSO7000/DS7000 快速指南
RIGOL 更换保险丝 如需更换保险丝,请使用仪器指定规格(AC 250 V,T3.15 A;5.
RIGOL 远程控制 中文 MSO7000/DS7000 系列数字示波器支持通过 USB 接口、LAN 接口和 GPIB 接口 与计算机进行通信从而实现远程控制。远程控制基于 SCPI(Standard Commands for Programmable Instruments)命令集实现。MSO7000/DS7000 系列数字示波 器支持两种远程控制方式:用户自定义编程和使用 PC 软件(如 RIGOL Ultra Sigma) 。 更多产品信息 1. 获取设备信息 按 Utility 系统 关于此示波器 您可获取设备信息,包括厂商、产 品型号、产品序列号和硬件版本号等。您也可以参考本手册中的“使用内 置帮助系统”内容打开“帮助”功能菜单,然后按 关于此示波器 键获取 设备信息。上述菜单操作,您也可以通过触摸屏功能实现。 2.