User Manual

RIGOL
8 RP1001C Users Guide
Specifications
These characteristics apply to an adjusted RP1001C current probe
installed on an oscilloscope of any brand. The oscilloscope must be
warmed up for at least 20 minutes and be in an environment with
the temperature at 10-30 and the humidity at 0-80%.
Electrical Characteristics
Current Range
10mV/A, 100mV/A
DC Accuracy,
typical
100mV/A: ±3% ±50mA
(50mA to 10A peak range)
10mV/A: ±4% ±50mA
(500mA to 40A peak range)
100mV/A: ±15% maximum
(40A peak to 100A peak range)
Gain versus
frequency, typical
See
Appendix 1 Gain versus
Frequency at 1 A Peak (Typical)
Max. Working
Current
See Voltage and Current Ratings
Max. Working
Voltage
See Voltage and Current Ratings
Max. Floating
Voltage
See
Voltage and Current Ratings
Frequency Range DC to 300kHz (-3dB)
Battery Type and
Life, typical
9V NEDA 1604A, IEC 6LR61
13 hours (1 each)