User manual

Chapter 2 Command System RIGOL
RSA3000 Programming Guide 2-169
Return Format
The query returns the output amplitude in scientific notation.
Example
The following command sets the output amplitude to -10 dB.
:SOURce:EXTernal:POWer:LEVel:IMMediate:AMPLitude -10
The following query returns -1.000000000e+01.
:SOURce:EXTernal:POWer:LEVel:IMMediate:AMPLitude?
:SOURce:TRACe:REFerence:STATe
Syntax
:SOURce:TRACe:REFerence:STATe OFF|ON|0|1
:SOURce:TRACe:REFerence:STATe?
Description
Sets whether to display the reference trace of normalization.
Queries whether to display the reference trace of normalization.
Parameter
Name
Type
Range
Default
——
Bool
OFF|ON|0|1
OFF|0
Remarks
This command is only valid when the tracking generator function is enabled.
Return Format
The query returns 0 or 1.
Example
The following command enables the reference trace.
:SOURce:TRACe:REF:STATe ON or :SOURce:TRACe:REF:STATe 1
The following query returns 1.
:SOURce:TRACe:REF:STATe?
:SOURce:TRACe:STORref
Syntax
:SOURce:TRACe:STORref
Description
Saves the reference trace of normalization.
Remarks
This command is only valid when the tracking generator function is enabled.