User manual

RIGOL Chapter 2 Command System
2-14 RSA3000 Programming Guide
Parameter
Name
Type
Range
Default
<rel_ampl>
Consecutive Real Number
0 dB to 100 dB
6 dB
Return Format
The query returns the peak offset in scientific notation.
Example
The following command sets the peak offset to 12 dB.
:CALCulate:MARKer:PEAK:EXCursion 12
The following query returns 1.200000e+01.
:CALCulate:MARKer:PEAK:EXCursion?
:CALCulate:MARKer:PEAK:EXCursion:STATe
Syntax
:CALCulate:MARKer:PEAK:EXCursion:STATe OFF|ON|0|1
:CALCulate:MARKer:PEAK:EXCursion:STATe?
Description
Enables or disables the peak offset function.
Queries the status of the peak offset function.
Parameter
Name
Type
Range
Default
——
Bool
OFF|ON|0|1
ON|1
Return Format
The query returns 0 or 1.
Example
The following command enables the peak offset function.
:CALCulate:MARKer:PEAK:EXCursion:STATe ON or :CALCulate:MARKer:PEAK:EXCursion:STATe 1
The following query returns 1.
:CALCulate:MARKer:PEAK:EXCursion:STATe?
:CALCulate:MARKer:PEAK:SEARch:MODE
Syntax
:CALCulate:MARKer:PEAK:SEARch:MODE PARameter|MAXimum
:CALCulate:MARKer:PEAK:SEARch:MODE?
Description
Sets the peak search mode.
Queries the peak search mode.
Parameter
Name
Type
Range
Default
——
Keyword
PARameter|MAXimum
MAXimum