Instructions

Table Of Contents
Chapter 2 Command System RIGOL
RSA5000 Programming Guide 2-169
:SOURce Commands
Command List:
:SOURce:CORRection:OFFSet
:SOURce[:EXTernal]:POWer[:LEVel][:IMMediate][:AMPLitude
]
:SOURce:TRACe:REFerence:STATe
:SOURce:TRACe:STORref
Remarks:
The :SOURce commands are only available for RSA5065-TG/RSA5032-TG working in GPSA mode.
:SOURce:CORRection:OFFSet
Syntax
:SOURce:CORRection:OFFSet <rel_ampl>
:SOURce:CORRection:OFFSet?
Description
Sets the offset of the output amplitude of the tracking generator.
Queries the offset of the output amplitude of the tracking generator.
Parameter
Name
Type
Range
Default
<rel_ampl>
Consecutive Real Number
-200 dB to 200 dB
0 dB
Return Format
The query returns the offset in scientific notation.
This parameter only changes the readout of the tracking generator output power, but does not affect the
actual output power.
Example
The following command sets the offset to 10 dB.
:SOURce:CORRection:OFFSet 10
The following query returns 1.000000000e+01.
:SOURce:CORRection:OFFSet?
:SOURce[:EXTernal]:POWer[:LEVel][:IMMediate][:AMPLitude]
Syntax
:SOURce[:EXTernal]:POWer[:LEVel][:IMMediate][:AMPLitude] <ampl>
:SOURce[:EXTernal]:POWer[:LEVel][:IMMediate][:AMPLitude]?
Description
Sets the output amplitude of the tracking generator.
Queries the output amplitude of the tracking generator.
Parameter
Name
Type
Range
Default
<ampl>
Consecutive Real Number
-40 dBm to 0 dBm
-10 dBm