Technical data

The advanced technological state of your
pellet fire is the result of years of tests in
laboratory and practice.
The practical advantages of your pellet
fire are convincing:
OPERATING COMFORT -
OPERATING SECURITY
The fire is controlled by a digital electronic
monitoring device together with a patented
„air sensor“ that controls the interaction of
a flue gas fan, worm conveyor, convection
fan and temperature monitoring.
This monitoring system guarantees an opti-
mum combustion and operating state.
Operation is reduced to a minimum - this
means no operating errors with optimum
operation at the same time.
HIGHEST EFFICIENCY -
LOWEST EMISSIONS
A very large heat exchanger surface together
with an optimum combustion air control
results in very good use of fuel.
Finely dosed pellet feed in an optimised
burner pot made from high quality cast
steel results in almost perfect combustion
with very good exhaust gas values - and that
is guaranteed in every phase of operation.
10
3. TECHNOLOGY
4. AUTOMATIC SAFETY FUNCTIONS
POWER FAILURE
After a brief power failure the operating
functions that were set before the power
failure are continued.
ON-mode (manual operation): The control
switches into ST (start phase) and the de-
vice then continues to run in ON-operation.
TM-mode (automatic operation): The contol
switches into ST (start phase) and the de-
vice then continues to run in TM-operation.
SB-mode (Standby-operation): The control
switches into SB operation after approx. 2
seconds.
Some smoke can be emitted when the
power fails. This does not last any longer
than three to five minutes and is not a safety
risk.
OVERHEATING
An excess temperature switch (OTB) swit-
ches the heater off automatically in the
case of overheating. After the fire has cooled
down it returns to the control programme.
However whether heating operation is
continued depends on the embers still in
the combustion pan. If no ignition takes
place when fuel feed is started again, then
the shutdown programme (cleaning, after-
running phase) is carried out. The fire must
be started again dependent on the pre-set
mode.
LOW TEMPERATURE SWITCH OFF
The fire switches off if it cools down below
a minimum temperature.
It can also switch off if starting takes too
long.
ELECTRIC EXCESS CURRENT CUT OUT
The fire is fitted with a main fuse (on the
rear of the fire) as protection against excess
current (Data as per Item 1)
ENGLISH
CAUTION! If the fire overheats it is imperative
that maintenance and cleaning work is carried
out.