1. Remove all packing and hardware from
inside of the unit by removing the outer
lter and inner lters.
2. The air ltration unit can be hung from
the ceiling. Hang the unit using four
eye bolts (A, Fig.01), and four joist
hooks (B, Fig.01) provided. Unit can
also sit on a bench by installing rubber
feet provided.
Fig.01
Assembly
!
!
WARNING
Mounts must be anchored to building
structure, which will support a minimum of
at least 100 pounds. Never mount to
surfaces such as dry wall or false ceiling
grids, etc.
Air Filtration Unit Placement:
The ideal location for an air ltration unit is centered in the shop ceiling mounted
approximately 7-8 feet in the air. Another good location is above an area where a
lot of sanding is done. Example, if you do lathe work, sand the workpiece in place
and have a sanding center nearby, hang the air ltration unit between both areas.
If hanging the unit is not an option it can be mounted on a bench. Again, near an
area that produces the most dust. Remove the four corner screws at the bottom
of the air itration unit and install the rubber feet.
Depending on shop size you may need more than one air itration unit, or may
have to choose a larger size. If you have questions regarding placement of the
air itration unit you can contact Tech Support at 1-877-884-5167 or by email at
techsupport@rikontools.com.