Technical data

13
5.3 Ultrasonic generator RL35
26 Generator module handle
The generator module can be removed using these
handles if necessary. The fixing screws for opening
the generator module are located above and below
the handles.
Never remove or replace the generator module
when it is plugged in (high voltage)! Do not touch
the conductor board, condensers charged with
high voltage!
27 LED bars
This display shows the power output during the
welding sequence. When the horn is not under a
load, i.e. swinging freely in the air, the display should
not exceed the 25% mark.
If the 100% mark is exceeded an error message
occurs.
28 "POWER" LED
Operation display
29 “US-TEST” key
Key for activating the ultrasonic test.
Do not touch the horn!
30 LED
"US-ON" ultrasound enabled
"VALVE" magnetic valve enabled
"ERROR" error output enabled
33
33
26
26
27
29
30
28