Technical data

8.4 Oscillator system
Work on the oscillator system (S1) only if the sup-
ply voltage is switched off! High-voltage!
Avoid contact with the RF socket (RF1) of the
hand welding unit.
Do not connect any measuring device to the RF
socket of the hand welding unit!
The built-in transducer contains an electrical
charge even after the generator has been switched
off!
8.5 Screw connection
After the horn has been in operation for a longer
period of time, disconnect it according to the
instructions in chapter 7 “Retooling” and check it
for cleanliness.
Tightening torque: 30 40 Nm
Black spots on the interface K1 can be cleaned as
follows:
1. Clean with an oil-free cleaning agent and a
cotton or paper cloth.
2. If the surface is uneven or has grooves, please
contact the appropriate service location.
22
HF1
S1