Technical data

8-4
RL35HWV40/GB/N
O
7768/16279
Retooling
8.2.2 Afterpulse (shake-off impulse)
The afterpulse can be activated with a jumper
on the main circuit board. The afterimpulse
occurs 0.3 seconds after the holding time has
expired.
J4 ”Hardware test program” jumper
(only for use by the manu-
facturer)
J5 ”US afterpulse” jumper
P Main circuit board
The standard setting of J4 and J5 is "OFF".
The time of the afterpulse can not
be changed.
25 ms
75 ms
UGF
5
8.2.3 Soft Start
The greatest strain on the transducer system
occurs when the oscillations are first stimula-
ted. To avoid overloading and resultant da-
mage, a soft-start device has been installed
in the RINCO generator, which can be conti-
nuously adjusted from 25ms to 75ms. Your
device is supplied with a setting of 50ms.
The adjustment potentiometer (P3) for the
soft-start device is located on the card modu-
le inside the housing in order to prevent
accidental alterations of the setting.
(Only UGF)
Important: Before switching on the
card module again, always make
sure that it is fully and correctly
reinserted (front panel flush).