Configuration Command Class
The sensor has the following supported configuration parameters.
Parameter
No.
Description
Number
of Bytes
Default Min Max Format
1
Heartbeats:
This parameter is the number minutes
between heartbeats. Heartbeats are au-
tomatic battery reports on a timer after
the last event.
1 70 (0x46) 1 (0x01) 70 (0x46)
0x01
Unsigned
2
Number of application level retries at-
tempted for messages either not ACKed
or messages encapsulated via supervi-
sion get that did not receive a report.
1 1 (0x01) 0 (0x00) 5 (0x05)
0x01
Unsigned
3
NApplication Level Retry Base Wait Time
Period:
The number base seconds used in the
calculation for sleeping between retry
messages.
1 5 (0x05) 1 (0x01) 60 (0x3C)
0x01
Unsigned
4
This parameter allows a user, via soft-
ware, to configure the various LED
indications on the device.
0 - Don’t show green
1 - Show green after Supervision Report
Intrusion (Fault)
2 - Show green after Supervision Report
both Intrusion and Intrusion clear
1 1 (0x00) 0 (0x00) 2 (0x01) enum
5
One shot timer:
Writing to this parameter prompts the
sensor to send a wakeup notification
one time after this parameter’s number
of seconds. After which it is reset back
to 0.
1
1500
(0x5DC)
5 (0x05)
65535
(0xFFFF)
0x01 Un-
signed
6
The number of milliseconds waiting for a
Supervisory Report response to a Super-
visory Get encapsulated command from
the sensor before attempting a retry.
2
10000
(0x2710)
500
(0x1F4)
30000
(0x7530)
0x01 Un-
signed
Group Identifier Max Nodes Description
1 (Lifeline) 0x05
1. Notification Report
a. See notification CC section for notifications that are sent
2. Battery Report
3. Device Reset Locally Notification
Association Command Class