Rinnai Tankless Water Heater Installaon and Operaon Manual 11
THIS SECTION IS INTENDED FOR THE INSTALLER
Installer qualicaons: A trained and qualied professional must install the appliance, inspect it, and leak test the water
heater before use. The warranty will be voided due to any improper installaon. The trained and qualied professional
should have skills such as: Gas sizing; Connecng gas lines, water lines, valves, and electricity; Knowledge of applicable
naonal, state, and local codes; Installing venng through a wall or roof; and training in installaon of tankless water
heaters. Training for Rinnai Tankless Water Heaters is accessible online at www.trainingevents.rinnai.us.
3. Install the Water Heater
3.1 Installaon Guidelines
• This water heater is suitable for combinaon water
heang and space heang and not suitable for space
heang applicaons only.
• The installaon must conform with local codes or, in
the absence of local codes, with the Naonal Fuel
Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas
and Propane Installaon Code, CSA B149.1.
• The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the Naonal Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.1.
• The appliance and its main gas valve must be
disconnected from the gas supply piping system
during any pressure tesng of that system at test
pressures in excess of 1/2 psi (3.5 kPa) (13.84 in
W.C.). For system tesng at pressures less than or
equal to 1/2 psi (3.5 kPa) (13.84 in W.C.) the
appliance must be isolated from the gas supply
piping by closing its individual manual shuto valve.
• You must follow the installaon instrucons and
those in secon “3.5 Vent the Water Heater” for
adequate combuson air and exhaust.
• If a water heater is installed in a closed water supply
system, such as one having a backow preventer in
the cold water supply line, means shall be provided
to control thermal expansion. Contact the water
supplier or local plumbing inspector on how to
control thermal expansion.
• Should overheang occur or the gas supply fail to
shut o, turn o the manual gas control valve to the
appliance.
(En cas de surchaue ou si l’alimentaon en gaz ne
s’arrête pas, fermez manuellement le robinet d’arrêt
de l’admission de gaz.)
• Combuson air must be free of chemicals, such as
chlorine or bleach, that produce fumes. These fumes
can damage components and reduce the life of your
appliance.
When installing the water heater, follow these guidelines:
DO NOT install the following internal (indoor)
water heaters outdoor: CU160i and CU199i
DO NOT install the following external (outdoor)
water heaters indoor: CU160e and CU199e
DO NOT install the water heater in an area
where water leakage of the unit or connecons
will result in damage to the area adjacent to the
appliance or to lower oors of the structure.
When such locaons cannot be avoided, it is
required that a suitable drain pan, adequately
drained, be installed under the water heater.
The pan must not restrict combuson air ow.
DO NOT install the water heater in an area with
negave air pressure.
DO NOT obstruct the ow of combuson and
venlaon air.
DO NOT use this appliance in an applicaon
such as a pool or spa heater that uses
chemically treated water. This appliance is
suitable for lling large or whirlpool spa tubs
with potable water.
DO NOT use substute parts that are not
authorized for this appliance.
DO NOT